Control interface for external devices
2.
SERIAL CONT 1 to 5 (RJ‑45)
Use LAN cables to connect Panasonic remote cameras with serial (RS422) connections. Connect them with straight cables (category 5e or better
shielded cable).
Pin
Signal name
number
1
GND
2
TALLY
3
TXD –
4
RXD –
5
RXD+
6
TXD+
7
NC
8
NC
z TALLY (pin number: 2) specifications
z
Voltage withstand: Max. 24 V DC
Current: Max. 50 mA
3.
IP CONT (RJ‑45)
Complies with 10BASE‑T/100BASE‑TX.
Allowing connection to a network device that supports the PoE standard (IEEE802.3af compliant).
4.
12V
IN (DC 12 V)
Hirose Electric: HA16RA‑4P (77)
Accepts DC 12 V inputs from an external power supply.
Input voltage range: 10.8 V to 13.2 V
Pin No.
1
2
3
4
(continued)
Description of signal
Frame ground
Tally output (open collector)
Send data (–)
Receive data (–)
Receive data (+)
Send data (+)
Not used
Not used
Function
1
GND
2
NC
3
NC
4
+12V