Others Settings - Nikon NPL-302 Series Instruction Manual

Pulse laser station
Table of Contents

Advertisement

5 Menu Key

Others settings

To open the Others menu, press
Other
in the Settings menu.
XYZ disp Fast/Norm/Slow/+ENT
Defines speed to move to the next
screen after showing XYZ of the
input PT
2nd Unit None/Meter/US-Ft/I-Ft
When the Secondary unit is set to a unit, an extra display screen is
available in the BMS, stakeout observation screens, and 2-pt
reference line screens. The extra screen shows the HD, VD, and SD
in the secondary unit.
If you select US-Ft or I-Ft, an additional settings
screen appears. Use this screen to specify
whether to display values in Decimal-Ft or Ft-
Inch.
Sig Beep ON/OFF
Split ST
No/Yes
Select Yes to separate the point numbers of station points from other
record type point numbers.
If you set the Split ST field to Yes, an additional
setting screen appears. Use this screen to specify
the starting ST number.
CD Input ABC/123
Sets the default input mode when a CD field appears.
140 Pulse Laser Station NPL-302 Series Instruction Manual
[9]
or select
51.9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Npl-332Npl-352Npl-362

Table of Contents