Specifications; General Description - Panasonic KX-TDA50 Installation Manual

Hybrid ip-pbx
Hide thumbs Also See for KX-TDA50:
Table of Contents

Advertisement

1.4
1.4.1
Switching
AC Adaptor
DC Input
Maximum Power Failure Tolerance 300 ms
Memory Backup Duration
Dialing
Connectors
Mode Conversion
Ring Frequency
Central Office Loop Limit
Operating
Environment
Conference Call CO Line
Music on Hold
Paging
Serial Interface
Port
Great user manuals database on

Specifications

General Description

AC Input
DC Output
CO Line
Extension
CO Line
Extension
Paging Output
External MOH
(Music on Hold)
Output
Temperature
Humidity
Internal
External
RS-232C
USB
UserManuals.info
Non-blocking
Panasonic PSLP1244: 100 V AC to 240 V AC; 1.5 A; 50 Hz/60 Hz
Panasonic PSLP1434: 110 V AC to 240 V AC; 1.35 A; 50 Hz/60 Hz
40 V; 1.38 A (55.2 W)
DC IN 1: 40 V; 1.38 A (55.2 W)
DC IN 2: 40 V; 1.38 A (55.2 W)
7 years
Dial Pulse (DP) 10 pps, 20 pps
Tone (DTMF) Dialing
Dial Pulse (DP) 10 pps, 20 pps
Tone (DTMF) Dialing
RJ11 (2 wire) × each CO ports
RJ11 (4 wire) × each extension ports
1 conductor jack
1 conductor jack
DP-DTMF, DTMF-DP
20 Hz/25 Hz (selectable)
1600 Ω maximum
0 °C to 40 °C (32 °F to 104 °F)
10 % to 90 % (non-condensing)
From 10 × 3-party conference call to 4 × 8-party conference call
1 port (Level Control: -11 dB to +11 dB in 1 dB steps)
Selectable Tone/External Music Source port
Level Control: -15 dB to +6 dB in 3 dB steps
1 port (Volume Control: -15 dB to +15 dB in 1 dB steps)
1 (maximum 115.2 kbps)
1