HMS Intesis WMP User Manual

Gateway for the integration of hitachi vrf systems into home automation systems
Hide thumbs Also See for Intesis WMP:

Advertisement

Quick Links

WMP
Hitachi VRF Air Conditioning
Gateway for the integration of Hitachi VRF systems into Home Automation systems
(WMP)
USER MANUAL
Issue date: 09/2020 r1.1 ENGLISH

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Intesis WMP and is the answer not in the manual?

Questions and answers

Summary of Contents for HMS Intesis WMP

  • Page 1 Hitachi VRF Air Conditioning Gateway for the integration of Hitachi VRF systems into Home Automation systems (WMP) USER MANUAL Issue date: 09/2020 r1.1 ENGLISH...
  • Page 2 HMS Industrial Networks reserves the right to modify its products in line with its policy of continuous product development. The information in this document shall therefore not be construed as a commitment on the part of HMS Industrial Networks and is subject to change without notice.
  • Page 3 Gateway for the integration of Hitachi VRF systems into Home Automation systems (WMP). ORDER CODE LEGACY ORDER CODE INMBSHIT016O000 HI-AC-MBS-16 INMBSHIT064O000 HI-AC-MBS-64 © HMS Industrial Networks S.L.U. - All rights reserved https://www.intesis.com This information is subject to change without notice 3 / 24...
  • Page 4: Table Of Contents

    6. Dimensions ................................. 19 7. AC Unit Types compatibility..........................20 8. Error codes for Indoor and Outdoor Units ......................21 © HMS Industrial Networks S.L.U. - All rights reserved https://www.intesis.com This information is subject to change without notice 4 / 24...
  • Page 5: Description

    The aim of this integration is to monitor and control Hitachi air conditioning systems, remotely, from a Home Automation system. To do it so, Intesis communicates with Intesis WMP protocol, allowing controlling and update the signals requested from the Home Automation hub.
  • Page 6: Functionality

    Number of indoor units Number of indoor units that can be controlled through Intesis * There are different models of Intesis WMP – Hitachi VRF each one with different capacity. The table above shows the capacity for the top model (with maximum capacity).
  • Page 7: Intesis Wmp Interface

    2. Intesis WMP interface In this section, a common description for all Intesis WMP series gateways is given, from the point of view of the Home Automation system which is called from now on internal system. Connection with the Hitachi VRF system is also called from now on external system.
  • Page 8: Connections

    Connect a USB storage device (not HDD) if required. Check the user manual for more information. Ensure proper space for all connectors when mounted (see IMENSIONS © HMS Industrial Networks S.L.U. - All rights reserved https://www.intesis.com This information is subject to change without notice...
  • Page 9: Power Device

    Ethernet: Using the Ethernet port of Intesis. • USB: Using the console port of Intesis, connect a USB cable from the console port to the PC. © HMS Industrial Networks S.L.U. - All rights reserved https://www.intesis.com This information is subject to change without notice...
  • Page 10: Set-Up Process And Troubleshooting

    Ethernet port of the gateway and the Hitachi VRF installation connected to the corresponding port. Connectors, connection cables, PC for the Configuration Tool usage and other auxiliary material, if needed, are not supplied by Intesis for this standard integration. Items supplied by HMS Networks for this integration are: • Intesis gateway.
  • Page 11: Configuration Tab

    In this section it is possible to configure the different settings for the USB host port. 4.2.4. Home Automation (WMP) system configuration These are the settings available for the Home Automation system (WMP communication): © HMS Industrial Networks S.L.U. - All rights reserved https://www.intesis.com This information is subject to change without notice...
  • Page 12: Hitachi Configuration

    Active. If it’s active (checkbox at Unit xx), ranging from 1 to 64 indoor units that will be integrated (maximum number of units will depend on Intesis model) © HMS Industrial Networks S.L.U. - All rights reserved https://www.intesis.com This information is subject to change without notice...
  • Page 13 A progress bar will appear during the scan, which will take up to a few minutes. After scan is complected, detected units will be shown in available units as follows: Figure 4.6 Intesis MAPS Scan Hitachi Units window with scan results © HMS Industrial Networks S.L.U. - All rights reserved https://www.intesis.com This information is subject to change without notice...
  • Page 14: Signals

    2.- Go to tab ‘Receive / Send’ of MAPS, and in Send section, press Send button. Intesis will reboot automatically once the new configuration is loaded. © HMS Industrial Networks S.L.U. - All rights reserved https://www.intesis.com This information is subject to change without notice...
  • Page 15: Diagnostic

    Signals Viewer to simulate the BMS behavior or to check the current values in the system. Figure 4.10 Diagnostic More information about the Diagnostic section can be found in the Configuraion Tool manual. © HMS Industrial Networks S.L.U. - All rights reserved https://www.intesis.com This information is subject to change without notice 15 / 24...
  • Page 16: Set-Up Procedure

    Intesis and the Home Automation hub or controller, check that those are operative: check the baud rate, the communication cable used to connect all devices and any other communication parameter. © HMS Industrial Networks S.L.U. - All rights reserved https://www.intesis.com This information is subject to change without notice...
  • Page 17 Home Automation (WMP) – Hitachi VRF ® Intesis User Manual r1.1 EN Figure 4.11 Enable COMMS © HMS Industrial Networks S.L.U. - All rights reserved https://www.intesis.com This information is subject to change without notice 17 / 24...
  • Page 18: Electrical & Mechanical Features

    ON: 120 Ω termination active Switch B Off: 120 Ω termination inactive (default) (SWB) Position 2-3: ON: Polarization active Off: Polarization inactive (default) © HMS Industrial Networks S.L.U. - All rights reserved https://www.intesis.com This information is subject to change without notice 18 / 24...
  • Page 19: Dimensions

    Recommended available space for its installation into a cabinet (wall or DIN rail mounting), with space enough for external connections 100 mm (h) 100 mm (w) 130 mm (d) © HMS Industrial Networks S.L.U. - All rights reserved https://www.intesis.com This information is subject to change without notice 19 / 24...
  • Page 20: Ac Unit Types Compatibility

    7. AC Unit Types compatibility A list of Hitachi unit model references compatible with INMBSHIT---O000 and their available features can be found https://www.intesis.com/docs/compatibilities/inxxxhit001r000_compatibility © HMS Industrial Networks S.L.U. - All rights reserved https://www.intesis.com This information is subject to change without notice...
  • Page 21: Error Codes For Indoor And Outdoor Units

    Outdoor Unit lncorrect Outdoor Unit Main Unit Setting. Two (or more) Outdoor Units Set as "Main Unit" Exist in Same Refrigeran! Cycle System. © HMS Industrial Networks S.L.U. - All rights reserved https://www.intesis.com This information is subject to change without notice...
  • Page 22 Setting of Main and Sub Unit(s) Combination or Voltage. Abnormality Transmission between Main Unit and Sub Unit(s). lncorrect Wiring, Disconnect Wire, Breaking Wire, PCB Failure. © HMS Industrial Networks S.L.U. - All rights reserved https://www.intesis.com This information is subject to change without notice...
  • Page 23 Abnormality of Fan Controller Sensor. Failure of Curren! Sensor (lnstantaneous Overcurrent, lncrease of Fin Temperature, Low Voltage, Earth Fault, Step-Out) © HMS Industrial Networks S.L.U. - All rights reserved https://www.intesis.com This information is subject to change without notice 23 / 24...
  • Page 24 In case you detect an error code not listed, contact the technical support of the respective AC manufacturer for more information on the error meaning. © HMS Industrial Networks S.L.U. - All rights reserved https://www.intesis.com This information is subject to change without notice...

Table of Contents