HMS Intesis INMBSHIS016O000 User Manual

Hisense vrf air conditioning gateway for the integration of hisense vrf systems into home automation systems

Advertisement

Quick Links

Hisense VRF Air Conditioning
Gateway for the integration of Hisense VRF systems into Home Automation systems
(WMP)
USER MANUAL
Issue date: 09/2020 r1.0 ENGLISH

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Intesis INMBSHIS016O000 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for HMS Intesis INMBSHIS016O000

  • Page 1 Hisense VRF Air Conditioning Gateway for the integration of Hisense VRF systems into Home Automation systems (WMP) USER MANUAL Issue date: 09/2020 r1.0 ENGLISH...
  • Page 2 HMS Industrial Networks reserves the right to modify its products in line with its policy of continuous product development. The information in this document shall therefore not be construed as a commitment on the part of HMS Industrial Networks and is subject to change without notice.
  • Page 3 Gateway for the integration of Hisense VRF systems into Home Automation systems (WMP). ORDER CODE LEGACY ORDER CODE INMBSHIS016O000 HS-AC-MBS-16 INMBSHIS064O000 HS-AC-MBS-64 © HMS Industrial Networks S.L.U. - All rights reserved https://www.intesis.com This information is subject to change without notice 3 / 24...
  • Page 4: Table Of Contents

    6. Dimensions ................................. 19 7. AC Unit Types compatibility..........................20 8. Error codes for Indoor and Outdoor Units ......................21 © HMS Industrial Networks S.L.U. - All rights reserved https://www.intesis.com This information is subject to change without notice 4 / 24...
  • Page 5: Description

    This document assumes that the user is familiar with Home Auotomation (WMP) and Hisense technologies and their technical terms. Integration of Hisense VRF compatible systems into Home Automation (WMP) systems. © HMS Industrial Networks S.L.U. - All rights reserved https://www.intesis.com This information is subject to change without notice...
  • Page 6: Functionality

    Their order codes are: ▪ INMBSHIS016O000, Model supporting up to 16 indoor units. ▪ INMBSHIS064O000, Model supporting up to 64 indoor units. © HMS Industrial Networks S.L.U. - All rights reserved https://www.intesis.com This information is subject to change without notice 6 / 24...
  • Page 7: Intesis Wmp Interface

    Acnum is given in the configuration section. See 4.2.5 H for more information. ISENSE CONFIGURATION © HMS Industrial Networks S.L.U. - All rights reserved https://www.intesis.com This information is subject to change without notice 7 / 24...
  • Page 8: Connections

    Connect a USB storage device (not HDD) if required. Check the user manual for more information. Ensure proper space for all connectors when mounted (see IMENSIONS © HMS Industrial Networks S.L.U. - All rights reserved https://www.intesis.com This information is subject to change without notice...
  • Page 9: Power Device

    Ethernet: Using the Ethernet port of Intesis. • USB: Using the console port of Intesis, connect a USB cable from the console port to the PC. © HMS Industrial Networks S.L.U. - All rights reserved https://www.intesis.com This information is subject to change without notice...
  • Page 10: Set-Up Process And Troubleshooting

    Ethernet port of the gateway and the Hisense VRF installation connected to the corresponding port. Connectors, connection cables, PC for the Configuration Tool usage and other auxiliary material, if needed, are not supplied by Intesis for this standard integration. Items supplied by HMS Networks for this integration are: • Intesis gateway. •...
  • Page 11: Configuration Tab

    In this section it is possible to configure the different settings for the USB host port. 4.2.4. Home Automation (WMP) system configuration These are the settings available for the Home Automation system (WMP communication): © HMS Industrial Networks S.L.U. - All rights reserved https://www.intesis.com This information is subject to change without notice...
  • Page 12: Hisense Configuration

    Intesis model) • IU address. Address 1..64 of Unit in Hisense H-Link bus. © HMS Industrial Networks S.L.U. - All rights reserved https://www.intesis.com This information is subject to change without notice 12 / 24...
  • Page 13 A progress bar will appear during the scan, which will take up to a few minutes. After scan is complected, detected units will be shown in available units as follows: © HMS Industrial Networks S.L.U. - All rights reserved https://www.intesis.com...
  • Page 14: Signals

    All available WMP signals, its corresponding description and other main parmaters are listed in the signals tab. The acnum of every unit is also displayed in a column in the signals view. © HMS Industrial Networks S.L.U. - All rights reserved https://www.intesis.com...
  • Page 15: Sending The Configuration To Intesis

    Diagnostic panels’ view or send commands to the gateway. • Viewers © HMS Industrial Networks S.L.U. - All rights reserved https://www.intesis.com This information is subject to change without notice 15 / 24...
  • Page 16: Set-Up Procedure

    8. Modify the configuration as desired, save it and download the configuration file to Intesis as explained in the Intesis MAPS user manual. © HMS Industrial Networks S.L.U. - All rights reserved https://www.intesis.com This information is subject to change without notice...
  • Page 17 Figure 4.15 Enable COMMS © HMS Industrial Networks S.L.U. - All rights reserved https://www.intesis.com This information is subject to change without notice...
  • Page 18: Electrical & Mechanical Features

    ON: 120 Ω termination active Switch B Off: 120 Ω termination inactive (default) (SWB) Position 2-3: ON: Polarization active Off: Polarization inactive (default) © HMS Industrial Networks S.L.U. - All rights reserved https://www.intesis.com This information is subject to change without notice 18 / 24...
  • Page 19: Dimensions

    Recommended available space for its installation into a cabinet (wall or DIN rail mounting), with space enough for external connections 100 mm (h) 100 mm (w) 130 mm (d) © HMS Industrial Networks S.L.U. - All rights reserved https://www.intesis.com This information is subject to change without notice 19 / 24...
  • Page 20: Ac Unit Types Compatibility

    7. AC Unit Types compatibility A list of Hisense unit model references compatible with INMBSHIS---O000 and their available features can be found https://www.intesis.com/docs/compatibilities/inxxxhis001r000_compatibility © HMS Industrial Networks S.L.U. - All rights reserved https://www.intesis.com This information is subject to change without notice...
  • Page 21: Error Codes For Indoor And Outdoor Units

    Discharge Gas Failure of Thermistor, Temperature lncorrect Wiring, lncorrect Piping Connection, Expansion Valve Locking at Closed Position (Disconnect Connector) © HMS Industrial Networks S.L.U. - All rights reserved https://www.intesis.com This information is subject to change without notice 21 / 24...
  • Page 22 Wire, PCB Failure Activation of Low Compression Ratio Defective Compression (Failure of Protection Device Compressor of lnverter, Loose Power © HMS Industrial Networks S.L.U. - All rights reserved https://www.intesis.com This information is subject to change without notice 22 / 24...
  • Page 23 NET Units are Connected to One System. lncorrect lndoor Unit Connection Number Setting 2 or more Switch Box Units are connected © HMS Industrial Networks S.L.U. - All rights reserved https://www.intesis.com This information is subject to change without notice 23 / 24...
  • Page 24 Switch Box Unit The indoor units of different refrigerant! cycle is connected to Switch Box unit. lncorrect lndoor Unit Connection © HMS Industrial Networks S.L.U. - All rights reserved https://www.intesis.com This information is subject to change without notice 24 / 24...

Table of Contents