Parameter Table - YASKAWA L1000H Quick Start Manual

Ac drive for elevator applications
Hide thumbs Also See for L1000H:
Table of Contents

Advertisement

7 Parameter Table

7
Parameter Table
This table below lists the most important parameters with
default settings appearing in bold type. Refer to the
Technical Manual for a complete list of parameters.
No.
Name
Initialization Parameters
0: English
1: Japanese
2: German
3: French
4: Italian
5: Spanish
6: Portuguese
7: Chinese
8: Czech
9: Russian
Language
10: Turkish
A1-00
Selection
11: Polish
12: Greek
Note:1. Language selection settings 8 to 12
can be selected from an LCD operator with
version (REV) F or later. The version
number of the LCD operator's PRG
software is shown on the back of the digital
operator.
Note:2. Language selection settings 8 to 12
are available in drive software PRG: 7017
or later.
0: View and set parameters A1-01 and
A1-04 (U- parameters can also be
viewed)
1: User Parameters (access to a set of
Access Level
A1-01
parameters selected by the user, A2-01 to
Selection
A2-32)
2: Advanced Access (access to view and set
all parameters)
3: Customer access
0: No initialization
1110: User Initialize (parameter values must
Initialize
A1-03
be stored using parameter o2-03)
Parameters
2220: 2-wire initialization
5550: oPE04 error reset
Operation Mode Selection
Up/Down
1: Digital input terminals
b1-02
Command
2: MEMOBUS/Modbus communications
Selection
3: Option Card
Output phase order with an Up command.
Phase Order
b1-14
0: U-V-W
Selection
1: U-W-V
Operation Mode Selection
Sets the frequency at which DC Injection
DC Injection
Braking starts when Ramp to Stop (b1-03 =
b2-01
Braking Start
3) is selected. If b2-01 < E1-09, DC
Frequency
Injection Braking starts at E1-09.
Sets the DC Injection Braking current as a
DC Injection
percentage of the drive rated current. In
b2-02
Braking
OLV the DC excitation current is
Current
determined by E2-03.
EN 33
Description
No.
Name
DC Injection
Sets the time of DC Injection Braking at
Braking Time/
b2-03
start in units of 0.01 seconds. Disabled
DC Excitation
when set to 0.00 seconds.
Time at Start
DC Injection
Sets the DC Injection Braking time at stop.
b2-04
Braking Time
Disabled when set to 0.00 seconds.
at Stop
Acceleration/ Deceleration
Acceleration
Sets the acceleration time 1 from 0 to the
C1-01
Time 1
max. output frequency.
Deceleration
Sets the deceleration time 1 from the max.
C1-02
Time 2
output frequency to 0.
Acceleration/
C1-03 to
Set the acceleration/deceleration times (set
Deceleration
C1-15
like C1-01/02).
Times 2 to 4
C2-01
S-Curve 1
S-curve at acceleration start.
C2-02
S-Curve 2
S-curve at acceleration end.
C2-03
S-Curve 3
S-curve at deceleration start.
C2-04
S-Curve 4
S-curve at deceleration end.
Slip Compensation
• Increase C3-01 if motor slip requires more
Slip
compensation (motor speed is lower than
C3-01
Compensation
speed reference).
Gain
• Decrease if slip is overcompensated.
Slip
• Decrease if the drive does not provide
Compensation
C3-02
motor slip compensation quickly enough.
Primary Delay
• Increase if motor oscillation occurs.
Time
Torque Compensation
Torque
• Increase C4-01 if torque response is slow.
C4-01
Compensation
• Decrease if speed/torque oscillations
Gain
occur.
Torque
• Increase C4-02 if speed/torque oscillation
C4-02
Compensation
occurs.
Delay Time
• Decrease if torque response is too slow.
Carrier Frequency
Carrier
Sets the carrier frequency. Settings above
C6-03
Frequency
the default requires output current derating.
V/f Pattern
This parameter must be set to the power
supply voltage.
Input Voltage
WARNING! Drive input voltage (not motor
E1-01
Setting
voltage) must be set in E1-01 for the
protective features of the drive to function
properly.
YASKAWA Europe TOEP C710616 92D AC Drive L1000H Quick Start Guide