Noise Data - Lindab SDJR-S Technical Manual

Smoke control damper
Table of Contents

Advertisement

Smoke Control Damper

10. Noise data

7.1. Sound power level corrected with filter A
Tab. 7.1.1. Sound power level Lw in dB(A) for B=250/300/450mm, damper fully open
f (Hz)
2
3
4
5
6
7
8
9
10
11
12
w - air velocity in the free cross section (AxB) - i.e. before blades
f - frequency of octave band
Tab. 7.1.2. Sound power level Lw in dB(A) for B=350/500/700/900/1100mm, damper fully open
f (Hz)
2
3
4
5
6
7
8
9
10
11
12
63
125
250
16
24
29
25
33
38
32
40
45
38
46
51
42
50
55
46
54
59
49
57
62
50
58
63
53
61
66
55
63
68
57
65
70
63
125
250
15
23
28
24
32
37
31
39
44
36
44
49
41
49
54
45
53
58
48
56
61
49
57
62
51
59
64
53
61
66
55
63
68
Lindab reserves the right to make changes without prior notice
Last modified: 2021-09-03
l in d a b | we s i mp l if y con s t r uct i on
500
1000
2000
29
28
38
37
45
44
51
50
55
54
59
58
62
61
63
62
66
65
68
67
70
69
500
1000
2000
28
27
37
36
44
43
49
48
54
53
58
57
61
60
62
61
64
63
66
65
68
67
Rev: 2021-03-26
SDJR-S
4000
8000
26
23
9
35
32
18
42
39
25
48
45
31
52
49
35
56
53
39
59
56
42
60
57
43
63
60
46
65
62
48
67
64
50
4000
8000
25
22
8
34
31
17
41
38
24
46
43
29
51
48
34
55
52
38
58
55
41
59
56
42
61
58
44
63
60
46
65
62
48
Total
35
44
51
57
61
65
68
69
72
74
76
Total
34
43
50
55
60
64
67
68
70
72
74
19