4.2.3 Possible connections exhaust air ...... 14 7.2 Open inlet faceplate ..........34 Possible combination of connections ....14 7.3 Opening inspection hatch ........35 Electrical connections ........15 8. Accessories ........... 36 Lindab reserves the right to make changes without prior notice 2024-01-05...
“Accessories”. towards the construction site. Lindab will also provide you with a full ventilation system, with a wide range of Lindab Safe components. See also Do not place the product directly on the floor. Use the “Air Duct Systems”.
Use plastic folio or other to protect the product during on site construction continually to keep the products in best condition and avoid any scratches. Lindab reserves the right to make changes without prior notice 2024-01-05...
Do not grab or pull the inlet face- plate frame or the water pipes. Boxes come in different sizes. 10-25 kg ! Lindab reserves the right to make changes without prior notice 2024-01-05...
Pos : Munio-I-xxx-12-125-AX x,xx m Pressure: AA Pa Flow: BB l/s Project : xxxxxx xxxxxxxx Mark : xxxxx Nozzles : N/A Plugs : N/A Sign. : Product ID : xxxxxxx Lindab reserves the right to make changes without prior notice 2024-01-05...
Plugs : N/A Sign. : Product ID : xxxxxxx • Mark: Marking noted on order. • Product ID: Product number. • Sign: To be signed when checked and commissioned on site. Lindab reserves the right to make changes without prior notice 2024-01-05...
Regula connect card /Regula Secura (plus feature). Go to Order no: 647690, 884050 and 642623 (12 mm).see Actuators for details. See also Adapter ring. Accessories Lindab reserves the right to make changes without prior notice 2024-01-05...
3. Product specification 3.3 Munio 3.1 Product description Lindab’s active chilled beam unit Munio can be used for cooling, heating and ventilation. It has been developed for the installation and integration into bulkheads in hotel- and hospital rooms or for any other rooms with bulkheads.
PN 10 according to EN 1333: 2006. This means the maximal working pressure for the pro- ducts at a water temperature of 20°C must not exceed 10 bar. Lindab reserves the right to make changes without prior notice 2024-01-05...
When connecting a panel or a beam with the piping system either a push-on fitting or a compression coupling should be used. Lindab have tested and recommends John Guest push on fittings as well as push-on fittings from Tectite (available as accessory. See Accessories).
• Please refer to the suppliers manual. = 70 mm (to ensure you can open the couplings again). Lindab flexible hoses are available with straight end (male) for direct connection to Lindab valves also. Lindab reserves the right to make changes without prior notice...
If the connection is a connection. The dimension for all connections are 12 “2-pipe”, as in a change-over system, or if Munio is to be used for cooling only, the heating connection can be left unconnected.
4.2.2 Possible connections supply air The Munio has one possible supply air connection (A) (horizontal back connection). To achieve other directions than horizontal we recommend using either a Lindab BKMU-90-125 or DRATMFU-125.
In and controlled by the Regula Secura. single rooms arrangements Regula Combi can also placed on a room wall to enable easy access. Regula components on the beam. Lindab reserves the right to make changes without prior notice 2024-01-05...
Supply link - L Supply in - N Supply in - 24V - L NB: Wire colours LINDAB differ from standard NB: Wire colours differ from standard Example 2 Wiring scheme. Lindab reserves the right to make changes without prior notice 2024-01-05...
Condensation sensor and Regula Secura Cable to Regula Secura Protection cap Condensation sensor Regula Secura with condensation sensor preinstalled on Munio battery cold water inlet pipe. Lindab reserves the right to make changes without prior notice 2024-01-05...
Ecophon - E / T15 Rock fo f f n Sonar X 584x584 599x599 575x575 T24/T15 Lay-in-625 ( I-62 ) Water T24/T15 Lay-in- ( I-62 ) Water not cleanable Lindab reserves the right to make changes without prior notice 2024-01-05...
5.3.5 Recessed in suspended (permanent) 5.3.2 Exposed, sealed to the ceiling. ceiling with cover flanges. 5.3.3 Exposed, free hanging. 5.3.6 Recessed in suspended (permanent) ceiling without cover flanges. Lindab reserves the right to make changes without prior notice 2024-01-05...
• Pendulum hangers (in different sizes) • Threaded rods M8 Munio-I suspension with threaded rods M8. Different types of hangers are available as accessory. L + 109 L + 22 Ø125 Min.
1775 1750 Table 2. Munio cutout sizes, dimensions and weights for different inlet face plates. *NB! Ceiling type 1 and 21 do not have a cutout. The inlet faceplates lay-in freely in T24/T15 ceilings. (Please check with ceiling supplier if weight is covered or hang separately.)
For all other scenarios, skip step- E. The inlet faceplate comes separately and the frame will not have to be de-installed/installed to the Munio. STEP-2 Remove the telescopic extension piece. Lindab reserves the right to make changes without prior notice 2024-01-05...
Page 23
Installation sketch for inlet faceplate -01/-21 with cutout dimensions. NB! Step 1-4 shows scenario when ceilings are built AFTER Munio are installed. If the ceiling is pre-built (sometimes the case for T-ceilings), step-4 will become step-1 and other steps 2-3-4.
Page 24
STEP-5 Installing telescopic expansion piece STEP-6 Insert outlet front grille 100 - 155 67-70 Installation sketch for Inlet faceplate -3 and -3E with cutout dimensions. Use 2x self drilling screws (not included). Lindab reserves the right to make changes without prior notice 2021-03-10...
Page 25
Start with the frame and the faceplate afterwards. NB! The frame can be used as a transition piece (0-10 mm) together with the screws for example to cover irregularities of or towards the ceiling. Lindab reserves the right to make changes without prior notice 2024-01-05...
Page 26
Recessed in suspended (permanent) ceiling with cover flanges 6 x 4.5x50 mm screws included. 100 - 155 2 x rails for inlet frame installation in plaster ceiling. Openable faceplate. De-install openable inlet faceplate from frame. Lindab reserves the right to make changes without prior notice 2024-01-05...
Page 27
A1 xB1. 6 x 4.5x50 mm screws included. Tighten screws until frame is firmly constrained to plaster ceiling. Installing inlet faceplate type 3S in ceiling type 3. Lindab reserves the right to make changes without prior notice 2024-01-05...
Page 28
Insert inlet faceplate. No tools needed. Faceplate lies freely in suspended ceiling. Check your ceiling system is properly hanged to take weight of the inlet faceplate. Lindab reserves the right to make changes without prior notice 2024-01-05...
The JetCone System enables an easy and fast adjustment in both pressure and air volume (primary airflow rate) through the front side. 6.1.1 Jetcone adjustment pins Hand-pull Hand-pull Positions Fixed parts Fixed parts Positioner Hand-pull Position 0 = Lukket Position 9 = Åben Lindab reserves the right to make changes without prior notice 2024-01-05...
Asymmetric adjustment Symmetric adjustment Symmetric adjustment of Jetcones, position 6 read from Asymmetric adjustment of Jetcones, position 4 and 8. diagram. Keep average value as read in diagram (=6). Lindab reserves the right to make changes without prior notice 2024-01-05...
• Find the mean value of the 2 pins to reach the desired airflow, in the diagram. Use the static nozzle pressure and the desired airflow to find the mean value of the two pins. • Adjust the two pins in the Munio, so the mean value of the pins will correspond with the mean value found in the diagram.
[Pa] stat [l/s] Munio 1200 Munio 1200 Position of JetCone adjustment pins ∆p [Pa] stat [l/s] Munio 1400 Munio 1400 Position of JetCone adjustment pins ∆p [Pa] stat [l/s] Lindab reserves the right to make changes without prior notice 2024-01-05...
LindQST\ waterborne calculator). Lindab refers to the proportional method, where all beams (panels or facade units) are balanced to the same proportion of the requested water flow rate. 7. Maintenance The interval of cleaning depends on the indoor environment where the beam is placed. Under optimal conditions the beams only need cleaning every 5 years.
| fo r a b e t te r c l i ma te Installation instruction Munio 7.3 Opening inspection hatch Dust-cleaner Vacuum cleaner Warning: Sharp edges Drill machine Lindab reserves the right to make changes without prior notice 2024-01-05...
| f o r a b et ter c lim at e Installation instruction Munio 8. Accessories Ask Lindab for the accessories mentioned in this document. Additional accessories (or additional dimensions) are available on request.** Order code Order number...
Page 37
We at Lindab have therefore made it our most important objective to contribute to an indoor climate that improves people’s lives. We do this by developing energy-efficient ventilation solutions and durable building products.
Need help?
Do you have a question about the Munio and is the answer not in the manual?
Questions and answers