Philips Semiconductors
7.11 SC16C2550 external reset condition
8. Limiting values
9397 750 11621
Product data
Dual UART with 16 bytes of transmit and receive FIFOs and IrDA
Table 22:
Reset state for registers
Register
Reset state
IER
IER[7-0] = 0
FCR
FCR[7-0] = 0
ISR
ISR[7-1] = 0; ISR[0] = 1
LCR
LCR[7-0] = 0
MCR
MCR[7-0] = 0
LSR
LSR[7] = 0; LSR[6-5] = 1; LSR[4-0] = 0
MSR
MSR[7-4] = input signals; MSR[3-0] = 0
SPR
SFR[7-0] = 1
DLL
DLL[7-0] = X
DLM
DLM[7-0] = X
Table 23:
Reset state for outputs
Output
Reset state
TXA, TXB
Logic 1
OP2A, OP2B
Logic 1
RTSA, RTSB
Logic 1
DTRA, DTRB
Logic 1
INTA, INTB
3-State condition
Table 24:
Limiting values
In accordance with the Absolute Maximum Rating System (IEC 60134).
Symbol
Parameter
V
supply voltage
CC
V
voltage at any pin
n
T
operating temperature
amb
T
storage temperature
stg
P
total power dissipation
tot(pack)
per package
Rev. 03 — 19 June 2003
Conditions
Min
-
GND − 0.3
−40
−65
-
© Koninklijke Philips Electronics N.V. 2003. All rights reserved.
SC16C2550
encoder/decoder
Max
Unit
7
V
V
+ 0.3
V
CC
°C
+85
°C
+150
500
mW
29 of 46