Vega VEGAWAVE 63 Operating Instructions Manual page 18

Vibrating level switch with tube extension for powders
Table of Contents

Advertisement

5 Connecting to power supply
Housing overview
Wiring plan
18
5
1
5
4
Fig. 9: Material versions, single chamber housing
1
Plastic (not with Ex d)
2
Aluminium
3
Stainless steel (not with Ex d)
4
Stainless steel, electropolished (not with Ex d)
5
Filter element for pressure compensation or blind plug with version IP 66/IP
68, 1 bar (not with Ex d)
We recommend connecting VEGAWAVE 63 in such a way that the
switching circuit is open when there is a level signal, line break or
failure (safe state).
The instrument is used to control relays, contactors, magnet valves,
warning lights, horns as well as PLC inputs.
Caution:
There is no reverse polarity protection. Take note of the polarity of the
output lines.
1
Fig. 10: Wiring plan
5
2
VEGAWAVE 63 • Transistor (NPN/PNP)
5
3