Restore The Delivery State - Beckhoff EPP3752-0000 Documentation

2 x 3-axis accelerometers
Table of Contents

Advertisement

5.3

Restore the delivery state

You can restore the delivery state of the backup objects as follows:
1. Ensure that TwinCAT is running in Config mode.
2. In CoE object 1011:0 "Restore default parameters" select parameter 1011:01 "Subindex 001".
3. Double-click on "Subindex 001".
ð The "Set Value Dialog" dialog box opens.
4. Enter the value 1684107116 in the "Dec" field.
Alternatively: enter the value 0x64616F6C in the "Hex" field.
5. Confirm with "OK".
ð All backup objects are reset to the delivery state.
Alternative restore value
With some older modules the backup objects can be changed with an alternative restore value:
Decimal value: 1819238756
Hexadecimal value: 0x6C6F6164
An incorrect entry for the restore value has no effect.
EPP3752-0000
Version: 1.2
Commissioning/Configuration
29

Advertisement

Table of Contents
loading

Table of Contents