Connectors - Beckhoff EPP3752-0000 Documentation

2 x 3-axis accelerometers
Table of Contents

Advertisement

Mounting and cabling
4.2.1

Connectors

Risk of damage to the device!
Bring the EtherCAT/EtherCAT P system into a safe, powered down state before starting installation, disas-
sembly or wiring of the modules!
Two M8 sockets at the upper end of the modules are provided for supply and downstream connection of
EtherCAT P:
• IN: left M8 socket for EtherCAT P supply
• OUT: right M8 socket for downstream connection of EtherCAT P
The metal threads of the M8 EtherCAT P sockets are internally linked to the FE connection via high
impedance RC combination. See chapter Functional earth (FE) [} 14].
1
1 - input
2 - downstream connection
Connection
4
2
3
1
Fig. 2: M8 socket, P-coded
Contact
Signal
1
Tx +
2
Rx +
3
Rx -
4
Tx -
Housing
Shield
1)
The core colors apply to EtherCAT P cables and ECP cables from Beckhoff.
16
2
Voltage
GND
S
GND
P
U
: peripheral voltage, +24 V
P
U
: control voltage, +24 V
S
Shield
Version: 1.2
NOTE
Core color 
yellow
white
blue
DC
orange
DC
Shield
1)
EPP3752-0000