NOTE: You are allowed to override the transducer type and size mounting mode and spacing
offset. See paragraph 1.7.
Now you have to mount the transducers in accordance with the data recommended on the screen. Refer
to the Section 3 for detailed instructions. The pipe must be completely filled with a liquid for the initial
installation of the meter. Make sure that you do not install your transducers backwards or reverse the
Upstream and Downstream cables.
Use the [Install Completed?] menu cell to inform the meter that you have finished mounting the
hardware. Press <Right Arrow>. Move the cursor to [Install]. Press <ENT>.
The meter performs an Initial Makeup which conditions its operation to the selected transducer, pipe
and liquid and then sets the empty pipe and the zero flow levels automatically. Be patient! The Initial
Makeup performs a number of operations including a frequency sweep of the pipe wall resonance,
which could take several minutes.