8.5.1.2 Play a Waveform - Manual Trigger
Description
User configures a sinusoidal waveform and plays it on a piezo actuator (channel A or B) by pressing the
Play button in the application.
Prerequisites
• Software is connected to the BOS1901-KIT board in Haptic mode.
2
Steps
1. Select a channel tab (A or B)
2. If the board is connected to a piezo actuator supplied in the BOS1901-KIT, click on the
corresponding piezo electric preset button to set the voltage operating range (Vmin and Vmax).
Otherwise, manually set the Vmin and Vmax fields in the Waveform section.
3. In the Triggers section, uncheck Sensing checkbox.
4. Configure the waveform:
o Sinusoidal waveform frequency (between 100.0 and 300.0 Hz)
o Number of cycles (between 1 and 254)
o Set the stabilization time (between 0 and 1000 ms)
5. In the Triggers section, click on Play button to play the wave on the piezoelectric actuator.
6. (Optional): Change the waveform parameters (Vmin, Vmax, Frequency, Cycles and Stabilization)
to see how it change the feedback when the play button is pressed.
BT001DDK04.01 – Issue 1
1
Figure 8:Play waveform – Manual trigger