3.4 Thermal Management
The driver temperature depends on the ambient and liquid temperature, as well as on the hydraulic operation
point. Figure 11, Figure 12 illustrate the temperature characteristics of the motor depending on these
parameters.
0.0
85
Absolute Thermal Limit
75
Recommended Operational
Temperature Limit
65
55
[°C]
45
35
25
0
Figure 11: Temperature curves for the IPD-600.2-50 driver @ 25 °C liquid temperature
(Typical data for pumping with pump head LPP-600.29, temperature is measured inside of the
integrated motor and controller, contact temperature of surface is below this temperature.)
0.0
85
Absolute Thermal Limit
75
65
[°C]
55
45
35
25
0
Figure 12: Temperature curves for the IPD-600.2-50 driver @ 70 °C liquid temperature
(Typical data for pumping with pump head LPP-600.29, temperature is measured inside of the integrated
motor and controller, contact temperature is below this temperature.)
PL-4089-00, Rev00, DCO# 21-271
[gallons / min]
5.0
10.0
9000 rpm
20
40
[liters / min]
[gallons / min]
5.0
10.0
9000 rpm
8000 rpm
20
40
[liters / min]
15.0
Ambient Temp = 25 °C
Liquid Temp. = 25° C
Specific gravity = 1 g/cm
Viscosity = 0.7 cP
8000 rpm
7000 rpm
60
15.0
7000 rpm
Recommended
Operational
Temperature Limit
Ambient Temp = 25 °C
Liquid Temp. = 70° C
Specific gravity = 1 g/cm
Viscosity = 0.7 cP
60
User Manual for BPS-i600
www.levitronix.com
20.0
177
3
157
137
6000 rpm
[°F]
117
5000 rpm
97
77
80
20.0
177
6000 rpm
157
5000 rpm
137
[°F]
117
97
3
77
80
13
Need help?