Technical Data - WEST PAM-140-P Technical Documentation Manual

Universal mobile power amplifier
Table of Contents

Advertisement

4.6 Technical data

Supply voltage
Current requirement
External protection
Analogue command input
Resolution
Reference voltage
PWM output
PWM frequency
Sample time (pressure control)
Sample time (solenoid current control)
Serial interface
Baudrate
Housing
Dimensions
Weight
Protection class
Temperature range
Storage temperature
Connections
Cable-cross section
EMC
Page 14 of 24
12... 30 (incl. ripple)
[VDC]
[mA]
< 50 + solenoid current
[A]
3 medium time lag
0... 10; 90 kOhm
[V]
[mA]
4...20; 240 Ohm
[%]
< 0,1 (intern 0,02) incl. oversampling
[V]
8 (max. 10 mA)
[A]
Max. 1 or 2.5 (selectable)
60... 2650 adjustable stepwise
[Hz]
[ms]
1
[ms]
0,167
LIN-bus
[kB]
19,2
PA 6-GB 30, Seal: CR
[mm]
98 x 64 x 34
[kg]
0,110
IP 65/DIN EN 60529
-20... 60
[°C]
-20... 70
[°C]
Push-in CAGE CLAMP
0.2... 1.5 / 24... 16 AWG
[mm²]
EN 61000-6-2: 8/2002
EN 61000-6-3: 6/2005
PAM-190-P-*-1010
18.08.2015