8.7.2

System environment variable (sev) area (IND = 01PPH (IND = 01H, PP = 00H, 01H))

sev Interface (IND = 01H, PP = 00H, sev_I, block I)
(1) Parameter clear
Parameter clear can be performed from the master.
IND
PNU
0100H
1H
0100H
2H
0100H
3H
0100H
5H
0100H
6H
* Communication parameters (Pr. 117 to Pr. 124, Pr. 338 to Pr.340, Pr.343, Pr. 349, Pr.549 to Pr.551) are not cleared.
Turning OFF the power supply while clearing parameters with 5A96H or AA99H also clears the communication parameter settings
back to the initial settings.
Item
Inverter reset
Parameter clear
All parameter clear
Parameter clear *
All parameter clear *
PPO TYPE NON-SUPPORT SPECIFICATION
Data Definition
965AH
99AAH
5A96H
AA99H