PARAMETER DEFINITIONS

6.2 IND = 01pph, System Environment Variable Area

6.2.1 IND = 0100h, pp = 00, SEV_I, Block I, SEV
Interface
PNU
0h
1h
2h
3h
4h
5h
6h
7h
Ah
Bh
Dh
Eh
WO: Write only, No Read.
*1 Bits 3, 4, 5, 6, 7, 8, and 9 can also be accessed from Pr 182, 181, 180, 185,
183, 184, and 186 respectively.
*2 Writing to Pnu=Dh or Pnu=Eh can be read out from Pnu=Dh.
*3 Due to the data write operation limits inherent to E
that running frequency be written to RAM whenever possible.
*4 Communication parameters (Pr. 117 to Pr. 124, Pr. 331 to Pr. 342) are not
cleared.
UsrClrValSet
WO:Inverter Reset
WO:PrClr,
WO:PrAllClr,
WO:PrUsrClr,
WO:PrClr (*4),
WO:PrAllClr (*4),
WO:PrUsrClr (*4),
Inverter Status/CtrlInpCmd, WriteVal = XXh
BIT
Inverter Status_ Word, see page 20 for details
Ctrl_Inp_Cmd_ Word (*1)
0
Reserved. Must be set to 0
1
1 = STF
2
1 = STR
3
1 = RH
4
1 = RM
5
1 = RL
6
1 = JOG
7
1 = RT
8
1 = AU
9
1 = CS
10
1 = MRS
11-15
Not used and always set to 0
See page 38 for examples.
OpMode/InverterConfig(Ext10h/Net14h),
Running frequency (RAM) (*2)
WO:Running frequency (E
Definition
WriteVal = 965Ah
WriteVal = 99AAh
WriteVal = 5A55h
WrtieVal = 5A96h
WriteVal = AA99h
WriteVal = 555Ah
WriteVal = 1Xh
2
PROM) (*2 & 3)
2
PROM, it is recommended
22