PPO TYPE NON-SUPPORT SPECIFICATION
8.2
ID definitions
ID
PKE
IND
PKW
(Refer to page 66)
PWE
ZSW
PZD
(Refer to page 69)
HIW
* Command request: Message from the master to the slave
Command response: Message from the slave to the master
8.3
Buffer memory map
The following shows the buffer memory map of the E5NP PROFIBUS profiles.
Module
1 Word
2 Words 3 Words 4 Words 5 Words 6 Words
type
E5NP
PKE
64
PNU number (PNU) and task or response Id (AK)
Index number
• Set 0 since high bits (Bits 16 to 31) are not used.
• Lower (Bits 0 to 15): Parameter value
• Bits 0 to 7: Inverter status (Command response)
• Set 0 since Bits 8 to 15 are not used.
Reserved area for extension
Reserved/
IND
PWE
Definition
Reserved/
HIW
ZSW