2) Set Sensitivity. The higher the value is, the easier the detection alarm will be triggered. Its
range is [0-100].
3) Click Draw Region, and draw a quadrilateral in the preview window.
7. Set the arming schedule. Refer to Configure Arming Schedule.
8. Set linkage actions. Refer to Configure Linkage Actions.
9. Click Apply.

5.5.4 Region Exiting Detection

Region exiting detection detects objects that exit from a predefined virtual region.
Steps
1. Go to System → Event → Smart Event.
2. Click Region Exiting.
3. Select a camera.
4. Check Enable Region Exiting Detection.
5. Optional: Check Save VCA Picture to save the captured region exiting detection pictures.
6. Follow these steps to set the detection rules and detection areas.
1) Select Arming Region. Up to 4 regions are selectable.
2) Set Sensitivity. The higher the value is, the more easily the detection alarm will be triggered.
Its range is [0-100].
3) Click Draw Region and draw a quadrilateral in the preview window.
7. Set the arming schedule. Refer to Configure Arming Schedule.
8. Set linkage actions. Refer to Configure Linkage Actions.
Digital Video Recorder User Manual