Choosing an Installation Location

AUTOMATIC SYSTEM ACTIVATION HAZARD
If the system is equipped with has an automatic
timer (user supplied) that activates the pump lubrica-
tion system when power is connected or when exit-
ing the programming function, unexpected activation
of the system could result in serious injury, including
skin injection and amputation.
Before you install or remove the lubrication pump
from the system, disconnect and isolate all power
supplies and relieve all pressure.
Select a location that will adequately support
the weight of the G3 Pump and lubricant, as
well as all plumbing and electrical connections.
Refer to the mounting hole layouts provided in
the Mounting Pattern section of this manual,
page 46. No other installation configuration
should be used.
Use designated mounting holes and provided
configurations only.
Always mount the G3 oil models upright.
12
Mount top fill G3 pump so that there is a mini-
mum clearance of four inches (4.0 in.) (10.2 cm)
above the reservoir to allow for lid removal and
filling.
If the G3 grease model is going to be operated
in a tilted or inverted position for any period of
time, you must use a model that includes a fol-
lower plate, otherwise the G3 must be mounted
upright. Refer to your model number to confirm
if a follower plate was installed on your pump.
See page 4, Understanding the Model Number
to identify this character in your model number.
Use the three fasteners (included) to secure the
G3 to the mounting surface.
Some installations may require an additional
reservoir support bracket. See table below for
bracket information.
In high vibration environments, additional isola-
tion at mounting point is necessary. See table
below.
AC pumps are not recommended when high
vibration or shock is present.
Part No Description
571159 Reservoir bracket and strap
125910 L-Bracket for pump