Manual Supplement
00809-0400-2410, Rev AA
1.3

Configuration using the FBM

The Rosemount 2410 Tank Hub is configured by using the Rosemount TankMaster
WinSetup configuration program
includes basic configuration options as well as advanced configuration and service
functions.
A Tank hub with two communication boards is normally configured using an FBM
configure the tank hub for Enraf emulation, do the following:
1.3.1
Set up Modbus communication protocol
This section describes how to configure the Modbus Master protocol channel for
communication with the FBM. Specify PC communication port and the standard
communication parameters: Baud rate, Parity, and number of Stop Bits.
1.
2.
3.
4.
1.
See the Rosemount Tank Gauging System Configuration Manual (document number 00809-0300-5100) for more information on how
to use the TankMaster WinSetup software to configure the Rosemount 2410 Tank Hub.
2.
A tank hub where the secondary field bus communicates via WirelessHART, can be configured by wireless communication with a Smart
Wireless Gateway.
Rosemount 2410 Tank Hub
Open the Protocols folder in the Workspace window.
Select the Modbus Master icon.
Right click the proper MbMaster icon and select Properties to configure the
protocol channel.
Select the Communication tab.
(1)
. WinSetup is a user-friendly software package that
Rosemount 2410 Tank Hub
March 2016
(2)
. To
7