Download Print this page

Emerson Rosemount 2410 Instructions Manual page 26

Hide thumbs Also See for Rosemount 2410:

Advertisement

Rosemount 2410 Tank Hub
March 2016
Change Enraf bus gain
The Enraf bus gain is by default 10 percent. A long cable and/or high impedance may result
in the need to increase gain. Increased gain will improve detection of weaker signals, but
also increase the risk of cross talk and EMC disturbance.
Table 1-8. Enraf Bus Gain Configuration Switch S1
SW1
SW2
OFF (Open)
OFF (Open)
ON (Closed)
Check switch status
The input registers can be used to check the current status of the switches without having
to dismount the communication board from the housing.
26
SW3
Gain
SW4
OFF (Open)
100%
ON (Closed)
32%
ON (Closed)
10% (default)
Manual Supplement
00809-0400-2410, Rev AA
SW3
ON (Closed)
SW4
SW2
SW1
To view current status of the
switches, left click the grey
background colored Value field for
the proper input register.
Rosemount 2410 Tank Hub
OFF (Open)

Advertisement

loading