PENBERTHY SUBMERSIBLE AUTOMATIC SUMP DRAINER
INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS
Before installation, these instructions must be read carefully and understood.

TABLE OF CONTENTS

Product warranty ................................................ 1
1
About the manual..................................... 2
2
Introduction ............................................. 2
2.1 System description ...................................... 2
2.2 Assembly ...................................................... 2
3
Available models ..................................... 2
operating temperature ranges ................... 3
4
Inspection ................................................ 3
5
Installation ............................................... 3
5.2 Mounting ....................................................... 3
6
Operation ................................................. 4
6.1 Pre-operational check ................................. 4
6.2 Start-up ........................................................ 4
7
Maintenance ............................................ 4
7.1 Preventative maintenance ........................... 4
7.2 Troubleshooting ........................................... 4
8
Disassembly - reassembly ...................... 5
9
Disposal at end of useful life ................... 5
10 Telephone assistance .............................. 5
11 Exploded parts diagram .......................... 6
Table 2 - Troubleshooting ................................ 4
Figure 1 - Exploded parts diagram ................... 6
Emerson.com/FinalControl

PRODUCT WARRANTY

Emerson warrants its Penberthy products
as designed and manufactured to be free
of defects in the material and workmanship
for a period of one year after the date of
installation or eighteen months after the date
of manufacture, whichever is earliest. Emerson
will, at its option, replace or repair any products
which fail during the warranty period due to
defective material or workmanship.
Prior to submitting any claim for warranty
service, the owner must submit proof of
purchase to Emerson and obtain written
authorization to return the product. Thereafter,
the product shall be returned to Emerson with
freight prepaid.
This warranty shall not apply if the product has
been disassembled, tampered with, repaired
or otherwise altered outside of the Emerson
factory or if it has been subject to misuse,
neglect or accident.
The responsibility of Emerson hereunder
is limited to repairing or replacing the
product at its expense. Emerson shall not be
liable for loss, damage or expenses related
directly or indirectly to the installation or use
of its products, or from any other cause or
for consequential damages. It is expressly
understood that Emerson is not responsible
for damage or injury caused to other products,
buildings, personnel or property, by reason of
the installation or use of its products.
This is Emerson's sole warranty and in lieu of
all other warranties, expressed or implied which
are hereby excluded, including in particular all
warranties of merchantability or fitness for a
particular purpose.
This document and the warranty contained
herein may not be modified and no other
warranty, expressed or implied, shall be made
by or on behalf of Emerson unless made in
writing and signed by the company's general
manager or director of engineering.
© 2018 Emerson. All Rights Reserved.
VCIOM-04068-EN 19/04

Advertisement

loading

Summary of Contents for Emerson PENBERTHY Series

  • Page 1: Table Of Contents

    10 Telephone assistance ......5 11 Exploded parts diagram ......6 This is Emerson's sole warranty and in lieu of all other warranties, expressed or implied which Tables and figures are hereby excluded, including in particular all...
  • Page 2: About The Manual

    Refer to the exploded parts view on page 6. installation, operation or maintenance. A. 2R-x Emerson does not have any control over the Discharge elbow to eductor manner in which its submersible automatic Place PTFE tape or equivalent on the male sump drainer is handled, installed or used.
  • Page 3: Maximum Design Pressure Ratings At Operating Temperature Ranges

    PENBERTHY SUBMERSIBLE AUTOMATIC SUMP DRAINER INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS 3.1 Maximum design pressure ratings at operating temperature ranges TABLE 1 Model Pressure Temperature 2R-W, 2R-WL, 2R-S and 2R-SL 200 psig [29 kPaG] -20°F to +150°F [-29°C to +302°C] 125 psig [18 kPaG] +400°F [+204°C] 4 INSPECTION The discharge pipe should be as short as...
  • Page 4: Operation

    PENBERTHY SUBMERSIBLE AUTOMATIC SUMP DRAINER INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS 6 OPERATION 7.2 Troubleshooting 6.1 Pre-operational check TABLE 2 Before start-up, the operator should ensure that: Problem Cause Solution a. All installation procedures have been Sump drainer fails 1. Suction piping is too restrictive 1.
  • Page 5: Disassembly-Reassembly

    (283) off prior to testing. You must obtain a Return Authorization removing the valve body. (R.A.) number from Emerson before returning 3. Remove the valve body plug (38). On 2R-L anything. Failure to do so will result in the unit models remove the adapter (134) as well.
  • Page 6: Exploded Parts Diagram

    Responsibility for proper selection, use, and maintenance of any product remains solely with the purchaser and end user. Penberthy is a mark owned by one of the companies in the Emerson Automation Solutions business unit of Emerson Electric Co. Emerson Automation Solutions, Emerson and the Emerson logo are trademarks and service marks of Emerson Electric Co.

This manual is also suitable for:

Penberthy 2r-slPenberthy 2r-wPenberthy 2r-sPenberthy 2r-wl