Jøtul F 35 130074_1 6/22
7.0 Accessory Installation
7.1 Short Leg Kit 157636
Approved for use only in existing code-approved masonry
fireplace hearth-mount installations.
Contents:
4 1/4" Steel Legs, (4)
Tools Required:
• 13 mm wrench or socket/ratchet
• work gloves
DO NOT LIFT THE STOVE UP BY THE ASH LIP.
1. Have an assistant tilt the stove up on one side enough to
remove the cast iron legs. Fully remove the nuts from the leg
studs.
2. Engage the steel leg with the mounting stud. Be certain the two
locating tabs on each leg seat with the corner pockets in the
stove bottom. Tighten the nuts and carefully set the stove back
down.

7.2 Outside Air Kit 157637

Contents:
• Outside Air Manifold
You will need the following additional components available at any
hardware supplier:
• Exterior Air Inlet Cover
• 4" Aluminum Duct
The exterior air inlet should be installed at a level lower than the stove
bottom.
1. Remove Bottom Heat Shield: Use the 10 mm socket driver or
wrench to remove the four nuts and the Bottom Heat Shield from
the studs in the stove bottom as shown in fig. 23. Also remove the
four remaining spacer nuts from the studs.
2. Attach the Outside Air Manifold directly to the stove bottom using
four of the nuts previously removed.
3. Use pliers to remove the air inlet cut-out from the bottom heat shield.
4. Attach the bottom heat shield to the outside air manifold using four
sheet metal screws from the Outside Air Kit.
If the bottom heat shield will not be used, install the sheet metal
screws supplied with the outside air kit to plug the associated holes
in the manifold.
7.3 Mobile Home Floor Bracket Kit 157321
Contents: Floor Brackets , (2)
Fastener Required: 3/8" dia. lag screw
1. Determine the final location of the stove and use the leveller
screws to plumb and level the stove.
2. Mount the floor brackets over the leveller screws at rear and
front locations at opposite corners and secure each to the floor
using a 3/8" dia. lag screw of appropriate length, (not supplied).
25
Tools Required:
• 10 mm and 1/4 " socket drivers
• safety glasses
• work gloves
• Rodent Screen
• 4" Duct Clamps, 2
CAUTION:
Avoid injury- always wear safety gloves when handling sheet metal
parts. Read through these instructions to familiarize yourself with
the parts before beginning the installation.
Figure 22.
Short Leg installation
Tab Pockets
Figure
23. Outside
Air Adaptor
installation.
Manifold
Nuts
Figure 24.
Floor Bracket Detail
Lag
Screw
Screw
Locator Tab
Remove four nuts and use to
attach the manifold.
Manifold
Manifold
Nuts
Heat Shield
Lag

Advertisement