3.4 Mobile Home Installation
The Jøtul F 35 is approved for installation in manufactured mobile
homes provided the following requirements are met:
1. All chimney components, including chimney sections, supports,
spark arrestor, etc., shall comply with the Standard for Factory-
built Chimneys for Residential Type and Building Heating
Appliances, UL 103 and/or CAN/ULC-S629 Standard for 650°C
Factory-built Chimneys.
2. The chimney shall be attached directly to the stove and extend
at least 3 ft. above the roof. Termination must be at least 2 ft.
above the highest elevation of any part of the mobile home within
10 ft. Close clearance pipe must be used.
3. All heat shields must remain on the stove.
4. In order to allow for transportation of the mobile home, the
chimney termination shall be readily removed at or below an
elevation of 13.5 ft. above ground level and reinstalled without use
of special tools or instructions.
5. A spark arrester must be installed at the termination. The
net free area of the arrester above the chimney outlet must not
be less than four times the net area of the chimney outlet, and
the vertical height of the arrester must not be less than one-half
the diameter of the chimney flue. Openings shall not permit the
passage of a sphere having a diameter larger than 1/2", and shall
permit the passage of a sphere having a diameter of 3/8".
6. Direct connection of the stove to an outside air source is
required. Use Outside Air Kit #157637 . Do not substitute any
other connection method or device. See Appendix, Section 7.0.
Duct termination must not be installed at a level that is higher
than the air inlet located at the bottom of the stove.
7. The stove must be secured to the mobile home floor. Use Floor
Bracket Kit 157321.
8. When the chimney exits the mobile home at a location other
than through the roof, and exits at a point 7 ft. or less above the
ground level, a guard or other method of enclosing the chimney,
must be provided at the point of exit for a height up to 7 ft.
Openings of this chimney guard shall not permit penetration of
a 3/4 in. diameter rod, or contact with the chimney by a 1/2 inch
diameter rod inserted through the opening a distance of
4 inches.
9. Provision must be made for electrical grounding of the chimney,
chimney connector, and stove in accordance with local building
codes.
WARNING: Do not install this appliance in a sleeping room.
CAUTION: The structural integrity of the mobile home floor,
walls, and ceiling/roof must be maintained.