Chimney Height; Wall Pass-Throughs - Jøtul Rockwood F 35 Installation And Operating Instructions Manual

Table of Contents

Advertisement

Jøtul F 35 130074_1 6/22
It will be necessary to cut wall studs, install headers, and construct
a sill frame to maintain the proper dimensions and to support the
weight of the brick.
The bricks must be solid brick with a minimum of 3 inches thick
(nominal 4").
Refractory mortar must be used at the junction of the chimney
and the pass-through liner. The pass-through liner must not
penetrate the chimney liner beyond the inner surface of the
chimney liner. Use extreme care when constructing the hole in
the chimney liner as the tiles can shatter easily.
In Canada
The installation must conform to CAN/CSA-B365, Installation
Code for Solid Fuel Burning Appliances and Equipment. Before
proceeding be sure to consult your local building inspector.
Common Method:
This method requires the removal of all combustible materials from
at least 18" around the chimney connector's proposed location. A
6" round liner requires a minimum opening 43" x 43" square.
Locate the pass-through at least 18" from combustible ceiling
materials.
The space that is cleared of combustible materials must remain
empty. Sheet metal panels can be used to cover the area. However,
when using a panel on both sides of the wall, each cover must be
installed on noncombustible spacers at least 1" from the wall. If
one panel of sheet metal is to be used it may be installed flush to
the wall.
See section 5.3.1 and 5.3.2 of CAN/CSA - B365-M91. Consult
your local building inspector, authorized Jøtul Dealer, NFPA 211
in the U.S. or CAN/CSA-B635 in Canada for other approved wall
pass-through methods.
8
Connector pipe must be
flush with the inside of
the flue tile
Chimney
Connector
Thimble
Figure 6.
Masonry Chimney Thimble.
Figure 7. Hearthmount Installation.
Flue Tile
Connector extends at least
into the first flue. Direct
connection to the chimney
cap is highly recommended.
Damper is sealed
with a steel plate
and high-tempera-
ture sealant.

Advertisement