Aerial Installation - ADC HiGain HRE-819 Manual

List 1, list 2 outdoor doubler enclosure
Table of Contents

Advertisement

Installation

Aerial Installation

To mount the doubler enclosure on a pole, use a 131B T-bracket and mounting bar assembly (ADC Part Number
132-1026-01), as shown in
Lug screw
1
Loosely install two of the T-bolts, nuts, and washers in one of the case-mounting brackets.
For mounting with stub up, install these bolts in the mounting bracket closest to the stub.
For mounting with stub down, install these bolts in the mounting bracket farthest from the stub. The bolts
engage the slots of the upper bar of the 131B T-bracket and support the case while you are installing the
lower mounting bolts.
2
Select a place for the 131B T-bracket. It can be mounted at any height on a pole, preferably near the aerial
cable or approximately 6 feet above ground level for easy access when used with buried or underground cable.
All necessary bolts, nuts and washers are included in the hardware installation kit.
3
3
Drill a
/
-inch diameter hole through the pole at the selected height.
4
5
4
Use the
/
-inch diameter suspension bolt, plus curved washers and a square nut, to fasten the top of the
8
131B T-bracket to the pole through the
10
Figure
7. This assembly allows the case to be mounted with the stub cable up or down.
T-bolt
Case-mounting
brackets
Figure 7. Vertical Pole Mounting at an Aerial Location
3
/
-inch hole.
4
Suspension bolt
131B T-bracket
131B Mounting bar
Pole
July 9, 1998
150-819-100-03
HRE-819 List 1 and 2