General Deployment Rules - ADC HiGain HRE-819 Manual

List 1, list 2 outdoor doubler enclosure
Table of Contents

Advertisement

150-819-100-03
Slot ID
Pressure
Pressure
Order Wire
Spare
Spare
Spare

General Deployment Rules

The HRE-819 is an air-tight enclosure. This environment traps the heat generated by the installed plugs causing
a significant heat rise within. The maximum number of doublers that can be reliably housed in the HRE-819 is a
function of the plug types.
The 239T1 repeater may occupy any number of slots without impacting the deployment rules.
Even when you obey the deployment rules, the metal surfaces of the installed units can feel hot to the touch when
removed from an HRE-819 that is operating in elevated ambient temperatures. This is a normal condition. The
plugs are designed to withstand these elevated temperatures.
Maximum Number of Doublers
With Full Solar
Load
12
10
8
6
4
All maximum ambient temperatures of 115°F or more comply with the outside deployment requirements
of section (10.2.1.3) in TA-NWT-001210.
HRE-819 List 1 and 2
Table 3. Interstitial Pair Terminations
Pair
BL-W
O-W
G-W
BR-W
SL-W
BL-R
Table 4
lists the HRE-819 deployment rules.
Table 4. HRE-819 Deployment Rules for Doublers
Without Full
HDU-409 and
Solar Load
HDU-219
12
115
°
F 46
12
125
°
F 52
10
135
°
F 57
8
145
°
F 63
6
155
°
F 68
July 9, 1998
Pin # in
Wire
Enclosure Housing
BL
8
W
9
O
11
W
10
-
-
-
-
-
-
-
-
Maximum Ambient Temperature*
HDU-439
°
C
105
°
F 40
°
C
°
C
115
°
F 46
°
C
°
C
125
°
F 52
°
C
°
C
135
°
F 57
°
C
°
C
145
°
F 63
°
C
Installation
17

Advertisement

Table of Contents
loading

This manual is also suitable for:

150-819-100-03

Table of Contents