ADC HiGain HRE-500 List 1 User Manual

Remote enclosure

Advertisement

Quick Links

U
M
SER
ANUAL
HRE-500 List 1
HiGain Remote Enclosure
Product Catalog: HRE-500-L1
CLEI: T1R4EGDC

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HiGain HRE-500 List 1 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ADC HiGain HRE-500 List 1

  • Page 1 ANUAL HRE-500 List 1 HiGain Remote Enclosure Product Catalog: HRE-500-L1 CLEI: T1R4EGDC...
  • Page 2 In no event shall ADC be liable for any damages resulting from loss of data, loss of use, or loss of profits, and ADC further disclaims any and all liability for indirect, incidental, special, consequential or other similar damages.
  • Page 3 Unpack each container and inspect the contents for signs of damage. If the equipment has been damaged in transit, immediately report the extent of damage to the transportation company and to ADC DSL Systems, Inc. Order replacement equipment, if necessary.
  • Page 4: Table Of Contents

    Table of Contents 150-500-100-05 ABLE OF ONTENTS Overview ________________________________________________1 Features ..................1 Applications................2 Product Description_______________________________________3 External Mechanics ..............4 Status LED ..............4 HRE-500 Stub ............5 Ground Wire ..............6 End Cap..............6 Internal Mechanics ..............7 Card-edge Connector ..........8 Gas-tube Protectors ............8 Thermal Deployment Limits........8 Bar Code and Configuration Number Information ....9 Installation _____________________________________________10 Installation Kit................10...
  • Page 5: Overview

    150-500-100-05 Overview VERVIEW ® ® The ADC HiGain Remote Enclosure Model HRE-500 List 1 is a weatherproof, outdoor, single-slot enclosure that houses one of the following units: • HiGain Mini Doublers – HDU-217 – HDU-219 – HDU-437 – HDU-439 •...
  • Page 6: Applications

    Overview 150-500-100-05 PPLICATIONS The HRE-500 List 1 houses doublers and allows quick and easy deployment of an ADC single or multi-doubler circuit, as shown in Figure Loop 1 Loop 1 Line Remote Doubler Loop 2 Loop 2 Unit Unit Span 1...
  • Page 7: Product Description

    150-500-100-05 Product Description RODUCT ESCRIPTION The HRE-500 List 1 includes: • External mechanics featuring: – Status LED viewing hole – 20-foot gel-filled stub – Ground wire – End cap • Internal mechanics featuring: – Card-edge connector – Gas-tube protectors HRE-500 List 1 July 25, 2002...
  • Page 8: External Mechanics

    Product Description 150-500-100-05 XTERNAL ECHANICS Figure 2 shows the external mechanics of the HRE-500 List 1 including the status LED viewing lens, cable stub wiring assignments and enclosure dimensions. Figure 2. HRE-500 List 1 External Mechanics Status LED The doubler single state LED can be viewed through the housing shown in Figure 2.
  • Page 9: Hre-500 Stub

    150-500-100-05 Product Description HRE-500 Stub The HRE has a 14 AWG, stranded ground wire and a four-pair, 20-foot gel-filled stub for access to the doubler’s four ports. This 24 AWG stub has foam skin insulation and a filled jacket. Each conductor has a dual insulation consisting of an inner coating of natural, insulating-grade, high-density cellular polyethylene covered by an outer skin of color-coded, high-density solid polyethylene.
  • Page 10: Ground Wire

    Product Description 150-500-100-05 Ground Wire The ground wire is required for both EMI and voltage surge protection for the installed doubler. End Cap There are five compression bolts on the end cap which work to create a waterproof barrier. When properly torqued, these bolts compress the neoprene washer (shown in Figure 4) that sits between the enclosure’s two...
  • Page 11: Internal Mechanics

    150-500-100-05 Product Description NTERNAL ECHANICS Figure 4 shows a front view of the HRE-500. Doubler Card-edge connector Gastube protectors Ferrite coil Neoprene washer Ground wire Stub Figure 4. HRE-500 List 1 Internal Mechanics HRE-500 List 1 July 25, 2002...
  • Page 12: Card-Edge Connector

    The tubes can withstand at least 400, 10/1000, 500 Amp discharges. A replacement kit containing 20, TII 47BT, gas-tube protectors is available from ADC (part #132-1028-01). See “Appendix B - Product Support” on page 16 for ordering information.
  • Page 13: Bar Code And Configuration Number Information

    150-500-100-05 Product Description ODE AND ONFIGURATION UMBER NFORMATION Figure 5 shows the locations of the bar code and configuration number labels. Table 1 gives a brief description of what the label represents. CLEI/ECI Configuration number bar code (on back plate) Figure 5.
  • Page 14: Installation

    NSTALLATION The HRE-500 installation kit components are listed in Table 2. If any items are missing, or if the shipment is damaged, please contact your ADC sales representative. Table 2. Installation Kit Part Number Quantity Description...
  • Page 15: Installing Doublers

    150-500-100-05 Installation NSTALLING OUBLERS To install a doubler in the HRE-500: Remove the small retaining screw from the lower front side of the case (see Figure 2 on page Loosen, but do not remove, the five compression bolts from the end cap (see Figure 2), then remove the end cap.
  • Page 16 Installation 150-500-100-05 Always follow the torquing sequence in Table 3. Exact torquing pressure is only required for installation in which the HRE-500 may be submerged in water. Approximate torquing is sufficient in all other installations. Table 3. Torque Sequence Chart Number Torque Sequence...
  • Page 17: Mounting The Enclosure

    150-500-100-05 Installation OUNTING THE NCLOSURE To mount the enclosure: Select a location for mounting the HRE-500 that allows access to wiring and grounding connections through the cable fittings on the bottom of the HRE-500. Place the HRE-500 in the chosen mounting location, then mark the mounting hole locations.
  • Page 18: Grounding

    Installation 150-500-100-05 Do one of the following: • If the installation location is wood, use a drill with a wood or metal drill bit to drill mounting screw holes into the surface. • If the installation location is concrete, use a drill with a concrete drill bit that is slightly smaller than the diameter of the anchor nuts to drill the mounting screw holes into the concrete surface.
  • Page 19: Appendix A - Specifications

    150-500-100-05 Appendix A - Specifications A - S PPENDIX PECIFICATIONS The HRE-500 List 1 outer enclosure has the following specifications: Length 12 in. (30.7 cm.) Width 3 in. (7.7 cm.) Depth 2 in. (5.12 cm.) Weight 2.5 lbs. (1.13 kg.) HRE-500 List 1 July 25, 2002...
  • Page 20: Appendix B - Product Support

    B - P PPENDIX RODUCT UPPORT ADC Customer Service Group provides expert pre-sales and post-sales support and training for all its products. Technical support is available 24 hours a day, 7 days a week by contacting the ADC Technical Assistance Center (TAC).
  • Page 21 150-500-100-05 Appendix B - Product Support • ADC Return Material Authorization (RMA) Product Return Department number and instructions must be obtained 800.366.3891 ext. 73748 or before returning products. 952.917.3748 Fax: 952.917.3237 Email: repair&return@adc.com All telephone numbers with an 800 prefix are toll-free in the USA and Canada.
  • Page 22: Appendix C - Glossary

    Appendix C - Glossary 150-500-100-05 C - G PPENDIX LOSSARY Abbreviations used throughout this manual are defined below: ANSI American National Standards Institute American Wire Gauge CLEI Common Language Equipment Identifier Central Office Equipment Catalog Item HiGain Doubler Unit ElectroMagnetic Interference ETPR Electro Thermo Plastic Rubber ETSI...
  • Page 23: Certification And Warranty

    ADC may use reconditioned parts for such repair or replacement. This warranty does not apply to any product which has been repaired, worked upon, or altered by persons not authorized by ADC or in ADC's sole judgment has subjected to misuse, accident, fire or other casualty, or operation beyond its design range.
  • Page 24 ADC DSL Systems, Inc. 14402 Franklin Avenue Tustin, CA 92780-7013 Tel: 714.832.9922 Fax: 714.832.9924 Technical Assistance Tel: 800.638.0031 Tel: 714.730.3222 Fax: 714.730.2400 ISO 9001/TL 9000 DNV Certification, Inc. REGISTERED FIRM : 150-500-100-05 OCUMENT ´,H&¶6$¨ 1240066...

This manual is also suitable for:

Hre-500-l1

Table of Contents