150-819-100-03
1
5
Use the
/
-inch lug screw at the bottom to fasten the mounting bar to the T-bracket and to keep the
2
131B T-bracket vertical on the pole.
6
Lift the case. (The recommended way to lift the case is to use a sling attached through the opening in the
doubler enclosure.) Secure the case to the mounting bracket with the four T-bolts.
7
Splice the stub. (See
spliced to either air-filled core cable or gel-filled core cable.
Enclosure cases spliced to air-core cable should be maintained under pressure from the cable. (See
"Pressurization" on page
Enclosure cases spliced to gel-filled cable above ground can be left unpressurized except in flood areas
where static pressurization is recommended. (See
8
Ground the enclosure.
All pole-mounted doubler enclosures must be grounded. Install a No. 6 AWG copper ground wire between
the case mounting bracket farthest from the stub cable and a 5-foot ground rod driven into the ground.
Doubler enclosure stubs with shields bounded to a properly grounded main cable shield do not
require this additional ground wire. Noise due to ground loops could occur if the case is
grounded both places.
S
S
PLICING THE
1
Locate the splice case.
2
Prepare the cable sheaths to prevent sharp edges from damaging the DEPIC insulation according to the
following steps.
Figure 8 on page 12
of the stub.
Ensure that the stub cable is properly bonded to the shield of the main cable if this is the only
means by which the double case is grounded.
The stub's screen should not be grounded nor should it be connected to other screens.
a
Cut the screen to length.
b
Flatten the screen as shown in
c
Fold the end of the screen on itself three times.
d
Reform the screen (unflatten) around the binder unit.
e
Wrap the folded end of screen with vinyl tape.
HRE-819 List 1 and 2
"Splicing the Stub Cable" on page
6.)
C
TUB
ABLE
shows the splice preparation.
Figure 8 on page
11). Enclosure cases mounted above ground can be
"Air Bypass Valve" on page
Figure 9 on page 12
12.
July 9, 1998
Installation
6.)
shows the cross section
11