ADC HiGain HRE-206 List 1 Technical Practice

Remote enclosure

Advertisement

Quick Links

HiGain
HiGain
T
P
ECHNICAL
RACTICE
HRE-206 List 1 Remote Enclosure
Part Number: 1146963
CLEI Code: T1MF50JG
HRE-206 List 2 Remote Enclosure
Part Number: 1146964
CLEI Code: T1MF60JG

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HiGain HRE-206 List 1 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ADC HiGain HRE-206 List 1

  • Page 1 HiGain HiGain ECHNICAL RACTICE HRE-206 List 1 Remote Enclosure Part Number: 1146963 CLEI Code: T1MF50JG HRE-206 List 2 Remote Enclosure Part Number: 1146964 CLEI Code: T1MF60JG...
  • Page 2 Contents herein are current as of the date of publication. ADC reserves the right to change the contents without prior notice. In no event shall ADC be liable for any damages resulting from loss of data, loss of use, or loss of profits, and ADC further disclaims any and all liability for indirect, incidental, special, consequential or other similar damages.
  • Page 3 Unpack each container and inspect the contents for signs of damage. If the equipment has been damaged in transit, immediately report the extent of damage to the transportation company and to ADC DSL Systems, Inc. Order replacement equipment, if necessary.
  • Page 4 Inspecting the Shipment LTPH-TP-1003-02, Issue 2 June 1, 2001 HRE-206 Lists 1 and 2...
  • Page 5: Table Of Contents

    LTPH-TP-1003-02, Issue 2 Table of Contents ABLE OF ONTENTS Overview ____________________________________________________________________________ 1 Features ..............................2 Applications ............................2 Backplane............................2 Slot Connectors ..........................4 Installation___________________________________________________________________________ 4 Installation Kit............................4 Mounting Options ..........................5 Desktop Mounting .......................5 Wall Mounting........................5 Turn-Up..............................7 Power and Grounding _________________________________________________________________ 7 48 Volt Power Options........................8 Slot Pin Assignments __________________________________________________________________ 9 HLU Alarm Output Interface......................13 Facility Side HDSL Connections .....................13...
  • Page 6 List of Figures LTPH-TP-1003-02, Issue 2 IST OF IGURES 1. HRE-206 List 1 and List 2 Remote Enclosure ....................1 2. HRE-206 Backplane............................2 3. Backplane Slot Connections (Slots 1 through 6).................... 3 4. HRE-206 Slot Connectors (front view)......................4 5.
  • Page 7: Overview

    LTPH-TP-1003-02, Issue 2 Overview VERVIEW ® The HiGain Remote Enclosure HRE-206 List 1 and List 2 house up to six 200-mechanics HiGain remote units (HRUs or H2TU-Rs), one protection switching controller card (PSC-606 List 1), and an optional power supply. The remote enclosure is used as a 1+1 (redundant) or 1+N (revertive or non-revertive) protection enclosure when the protection switching controller card is installed.
  • Page 8: Features

    Overview LTPH-TP-1003-02, Issue 2 EATURES The HRE-206 provides the following features: • Six 200-mechanics (or three 400-mechanics) card slots and one 400-mechanics power supply slot • One PSC-606 protection switching controller card slot (slot 7) • RJ48C (List 1) or RJ48X (List 2) modular jacks for DS1 customer interface connections •...
  • Page 9 LTPH-TP-1003-02, Issue 2 Overview Table 1. Backplane Connectors Connector(s) Function J9 through J14 RJ48C CPE jacks (List 1) or RJ48X jacks (List 2) Terminal block connector for Slot 1 CPE (DS1) and FAC (HDSL) interfaces Terminal block connector for Slot 2 CPE and FAC interfaces Terminal block connector for Slot 3 CPE and FAC interfaces Terminal block connector for Slot 4 CPE and FAC interfaces Terminal block connector for Slot 5 CPE and FAC interfaces...
  • Page 10: Slot Connectors

    Installation LTPH-TP-1003-02, Issue 2 ONNECTORS Figure 4 shows the front view of slot connectors J1 through J6 for installing HiGain line units and HiGain remote units. Slot connectors J7 and J8 are for installing the protection switch controller card (PSC-606) and the power supply module respectively.
  • Page 11: Mounting Options

    The HRE-206 is suitable for mounting on a desktop or on a wall. Before setting up the equipment, select a location that will provide appropriate security. Regardless of where the HRE-206 is mounted, ADC recommends that the frame-ground lug (pin 27) should be connected to earth ground according to the grounding recommendations found in Section 9 of Bellcore’s GR-1089-DEC 1996.
  • Page 12 Installation LTPH-TP-1003-02, Issue 2 Use the backplate as a template to mark the wall locations for drilling the mounting holes (Figure Mounting holes 0.00" Mounting holes Figure 6. HRE-206 Backplate Drill pilot holes and attach the backplate to the backboard with the four No. 10 x -inch sheet metal screws and washers supplied with the remote enclosure.
  • Page 13: Turn-Up

    • HRU-512, List xx • ERU-412, List xx ADC recommends that the frame ground lug on the outside of the enclosure be connected to earth ground according to the grounding recommendations found in Section 9 of Bellcore’s GR-1089-DEC 1996. Failure to properly ground the enclosure can cause unsafe voltage levels to occur which can result in the following adverse situations: •...
  • Page 14: Volt Power Options

    Power and Grounding LTPH-TP-1003-02, Issue 2 48 V OWER PTIONS When using the HRE-206 to locally power HRU plugs or HLU-431 and HLU-432 line units, -48 Vdc power is provided at terminal block TB8, the pin assignment for which is shown in Figure -48 Vdc All backplane...
  • Page 15: Slot Pin Assignments

    LTPH-TP-1003-02, Issue 2 Slot Pin Assignments SSIGNMENTS The following sections show the connector pin assignments of the HiGain plugs which are compatible with the HRE-206. Slot pin assignments for the various plugs compatible with the HRE-206 are shown in the following figures: •...
  • Page 16 Slot Pin Assignments LTPH-TP-1003-02, Issue 2 DS1Tip DS1 Ring HDSL L2 Ring 1 HDSL L2Tip 1 -48Vdc Chassis ground Fuse alarm Alarm 48Vdc local power supply Factory burn-in (do not use) Circuit ground DS1 Ring HDSL L1 Ring HDSL L1Tip DS1Tip 1 Chassis ground Note: Active pins are highlighted in black.
  • Page 17 LTPH-TP-1003-02, Issue 2 Slot Pin Assignments Ω G.703 Ring HDSL L2 Ring 1 HDSL L2Tip 1 -48Vdc 48Vdc local power supply Circuit ground Ring 1 HDSL L1 Ring Ω G.703 HDSL L1Tip Tip 1 Chassis ground Note: Active pins are highlighted in black. Chassis ground may be tied to earth ground according to local practice.
  • Page 18 Slot Pin Assignments LTPH-TP-1003-02, Issue 2 DS1 Tip DS1 Ring Ring HDSL2 span** Factory use only Factory use only -48Vdc Chassis ground* 48Vdc local power supply Factory use only Circuit ground DS1 Ring 1 Ring HDSL2 span DS1 Tip 1 Chassis ground Note: Active pins are highlighted in black.
  • Page 19: Hlu Alarm Output Interface

    LTPH-TP-1003-02, Issue 2 Slot Pin Assignments HLU A LARM UTPUT NTERFACE When HLU-431 or HLU-432 line units are installed in the HRE-206, the system alarm relay contacts for each slot, Normally Open (NO) and Common (COM), are bused together and made available on the Euro style terminal block TB8.
  • Page 20 Slot Pin Assignments LTPH-TP-1003-02, Issue 2 S l o t s 5 a n d 6 TB5-TB6 DS1_T_Tip_IN DS1_T_Ring_IN DS1_R_Tip_OUT DS1_R_Ring_OUT HDSL Tip L1 HDSL Ring L1 HDSL Tip L2 HDSL Ring L2 Figure 15. TB5 and TB6 Pin Assignments Loop 1 connects to the Tip and Ring leads.
  • Page 21: Cpe Ds1 (G.703) Connections

    LTPH-TP-1003-02, Issue 2 Slot Pin Assignments CPE DS1 (G.703) C ONNECTIONS The DS1 (G.703) XMT and RCV interfaces are available at either the Euro style terminals, CPE1 (J9) through CPE4 (J14) RJ48 jacks, as shown in Figure 2 on page 2, or by wire-wrap at each connector.
  • Page 22 Slot Pin Assignments LTPH-TP-1003-02, Issue 2 J9-J14 Metallic loopback connections (when jack is empty) Figure 17. RJ48X Pin Assignments (List 2) June 1, 2001 HRE-206 Lists 1 and 2...
  • Page 23: Appendix A - Specifications

    LTPH-TP-1003-02, Issue 2 Appendix A - Specifications A - S PPENDIX PECIFICATIONS Eight plug slots: Mounting • Six type 200 mechanics plugs • Three type 400 mechanics plugs • One type 200 protection switching controller card • One type 400 power supply module Telco Facility Euro style terminal blocks or wire-wrap pins RJ48 Connector Options:...
  • Page 24: Appendixb - Product Support

    ADC Customer Service Group provides expert pre-sales and post-sales support and training for all its products. ECHNICAL UPPORT Technical support is available 24 hours a day, 7 days a week by contacting the ADC Technical Assistance Center (TAC) at one of the following numbers: •...
  • Page 25: Appendixc - Abbreviations

    LTPH-TP-1003-02, Issue 2 Appendix C - Abbreviations C - A PPENDIX BBREVIATIONS AWG: American Wire Gauge BNC: Bayonet-Locking Connector CHREV: Channels Reversed COM: Common CPE: Customer Premises Equipment DS1: Digital Signal, level 1 EMI: Electromagnetic Interference ERU: ETSI Remote Unit ETSI: European Telecommunications Standards Institute HCDS: High Capacity Digital Service...
  • Page 26 Appendix C - Abbreviations LTPH-TP-1003-02, Issue 2 June 1, 2001 HRE-206 Lists 1 and 2...
  • Page 27: Certification And Warranty

    ADC during the 90-day warranty period is, at ADC’s option, either (a) return of the price paid or (b) repair or replace of the software. ADC also warrants that, for a period of thirty (30) days from the date of purchase, the media on which software is stored will be free from material defects under normal use.
  • Page 28 ADC DSL Systems, Inc. 14402 Franklin Avenue Tustin, CA 92780-7013 Tel: 714.832.9922 Fax: 714.832.9924 Technical Assistance 800.638.0031 714.730.3222 : LTPH-TP-1003-02, I OCUMENT SSUE ISO 9001 ´+qA¶7d¨ DNV Certification, Inc. Certificated Firm 1181337...

This manual is also suitable for:

Higain hre-206 list 211469631146964

Table of Contents