150-819-100-03
.
Desiccant space
Desiccant space

Gel-filled Stub - HRE-819 List 1 Only

The gel-filled, screened, 54-pair, 24-AWG cable stub on the List 1 unit is equivalent to an ALP FSS-PIC
filled-core telephone cable. It has a foam skin insulation with a single, filled jacket intended for buried, aerial,
and duct applications. Each conductor has a dual insulation consisting of an inner coating of natural,
insulating-grade, high-density, cellular polyethylene covered by an outer skin of color-coded, high-density, solid
polyethylene. Standard color codes are used for pair identification with color compounds chosen for electrical
balance and permanency (See
S-84-608-1994. The outside diameter of the cable is 0.85 inches.

Air-filled Stub - HRE-819 List 2 Only

The plastic-insulated single-jacketed air-core cable stub on the List 2 unit is intended for buried, aerial, and duct
applications. Conductors are insulated with solid, high-density polyethylene. Standard color codes are used for
pair identification with color compounds chosen for electrical balance and permanency. The cable complies with
the requirements of ANSI/ICEA S -85-625-1996. The outside diameter of the cable is 0.85 inches.
HRE-819 List 1 and 2
5
12
4
11
10
1
5
6
4
5
4
1
Figure 4. HRE-819 Housing
Figure 9 on page
12). The cable complies with the requirements of ANSI/ICEA
July 9, 1998
9
2
P
Pressure slot
8
Desiccant space
Lid-mounting
bolt holes
3
7
Torquing sequence
6
3
2
6
Desiccant space
2
3
1
6
Overview
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

150-819-100-03

Table of Contents