Troubleshooting - Delta FOUL V3 Installation Manual

Table of Contents

Advertisement

In no event shall we be liable for any consequential damage, penalties, loss, or expenses howsoever
arising, out of or in connection with incorrect installations, including, without limitation, direct or indirect
loss, consequential loss or damage, loss of profit or goodwill, loss arising from any errors or omissions
in the pump chamber as a result of, incorrect installation, installation/installer error, abnormal working
conditions, misuse, or neglect.
We shall not accept liability if the pumping system fails due to being incorrectly specified by any third
parties not employed by Delta Membrane Systems Limited.
We shall not accept liability if the pump system fails due to discharge of inappropriate fluids/solids
including, but not limited to, building debris or materials.

9. Troubleshooting

9.0 TROUBLESHOOTING
Please ensure the installation process has been completed thoroughly and all steps have been
followed correctly.
Use the table below to assist with troubleshooting and if problems still occur, please contact the Delta
Technical Department on 01992 523 523 from 9:00am - 5:00pm or email pumps@deltamembranes.com
Fault
Water leaking from DC65.
Pump isn't running.
Pump running but not pumping water
or discharging very slow (more than 25
seconds to empty chamber).
Pump is tripping.
High Level Alarm not functioning.
Cause
Screws not tightened sufficiently.
Pump hasn't got power - check wiring with reference to section 6.0
wiring diagram.
Float isn't lifting - check float is free moving and not catching on
chamber - make sure pump is positioned as diagram 34.
Pump is air locked - make sure there is a level of water to the top of
the pump, remove pump from DC65 and lower back into water, lift
float to activate pump before reconnecting the DC65.
Discharge pipe is blocked - a drainage company is required.
Pump is wired incorrectly or not on a separate supply - refer to section
6.0 wiring diagram.
Refer to the high level alarm installation & operating instructions.
01992 523 523 | info@deltamembranes.com | www.deltamembranes.com