6. Wiring Diagram

12.0
Wiring Diagram (inc. AlertMaxx2)
6.0 WIRING DIAGRAM
13 Amp Non-switched
fused spur
Separate 16 Amp RCBO
Pendant Float Switch
Supplied with a 10m cable
- The pump is supplied with a 10m cable.
- When only using the standard 10m
cable attached to the pump, the cable
duct should be no longer than 6m.
- If the cable duct requires to be longer
than 6m, please follow the cable
extension guide to select an appropriate
cable core diameter.
The electrical installation must comply with the requirements of
BS 7671:2018 'Requirements for
Electrical Installations' incorporating amendment 3:2015
01992 523 523 | info@deltamembranes.com | www.deltamembranes.com
AlertMaxx2 EC High Level Alarm
(DMS-599)
For internal wiring of the high
level alarm, please refer to the
AlertMaxx2 EC instruction manual.
Delta Foul V3
19