Control Panel Calibration Procedure:
• Connect control panel plug to engine wiring loom plug.
• Turn ignition on (do not start engine).
• Press and hold black button on rear of tacho until "H-"appears on the digital display at
the bottom of the tacho (on the front).
• When pressing and holding the black button on rear of tacho, the value displayed will
increase / decrease until the button is released. Then when pressing again it will
increase / decrease in the other direction. Keep doing this until the digitally displayed
value on the bottom of tacho reaches the correct value, according to the type of
alternator (see below table). This must be set to the alternator with blue and black
wire connected to it.
• Confirm settings to tacho meter reader.
• An optical tachometer is required to check the reading.
Barrus Alternator (Amps)
Alternative or non-standard alternators will require calibrating and checking by trial and error,
with a hand held tacho until the engine speed and indicated tachometer speed are the same.
For the majority of the engines, the tacho is driven by the 50A alternator.
• The Shire 70 has an energised to run system.

18. Exhaust System

EXHAUST HAZARD! NEVER OPERATE ENGINE WITHOUT PROPER VENTILATION.
NEVER BLOCK VENTS OR OTHER MEANS OF VENTILATION. ALL COMBUSTION
ENGINES CREATE CARBON MONOXIDE GAS DURING OPERATION.
ACCUMULATION OF THIS GAS COULD CAUSE ILLNESS OR EVEN DEATH.
Work Boat with Dry Exhaust:
The exhaust outlet size on the engine is 2" BSP female. There must be a flexible exhaust
hose of suitable exhaust grade between the engine and the silencer or hull outlet. The outlet
must be above the waterline at all times.
Exhaust silencers, flexible exhaust hose connections and lagging blanket are all available as
optional extras:
RDG603A81 – Issue 2
50
Barrus Tacho reading
10.50 – 11.00
WARNING: