5. Set the desired minimum and maximum pressure
limits for the inlet, and the desired maximum pres-
sure limit for the outlet.
6. Set the error type (alarm or deviation) that will be
issued:
If the minimum inlet pressure decreases below
the setting.
If the maximum inlet pressure increases above
the setting.
If the maximum outlet pressure increases above
the setting.
7. Press
to exit edit mode.
313377B

Configure Errors

Set the error type (alarm or deviation) that will be issued
if the pressure, flow rate, volume, or computed target
goes outside the set high and/or low limits. See Jobs,
page 40, for information on the purpose of each error
type.
NOTE: Only the first two error types (low pressure
and high pressure) will be enabled for systems with-
out a flow meter.
1. With the system in setup mode, navigate to the Fluid
Plate set of screens.
2. Press
to scroll to the Error Type screen
(screen 6).
3. Press
to access the fields to make changes.
F
. 27
IG
4. Press
to open the Low Pressure drop-down
list, and select either Alarm or Deviation for the error
type. Press
to enter the selection.
5. Press
to move to the next field. Repeat Step 4
for each field.
6. Press
to exit edit mode.