Configure Delay Settings

Set on and off delays (in milliseconds) for each gun and
the regulator. For an explanation of the on and off
delays, refer to the On/Off Delays section on page 35.
1. With the system in setup mode, navigate to the Fluid
Plate set of screens.
2. Press
to scroll to the Delay Settings
screen (screen 3).
3. Press
to access the fields to make changes.
F
. 24
IG
4. Use the four arrow buttons to navigate to each On
and Off field. Enter a desired delay value (in milli-
seconds) for each gun that will be used and the reg-
ulator. Press
to enter each value.
5. Press
to exit edit mode.
313377B

Configure Flow Meter Settings

The accuracy of the PCF volume reporting depends on
precise adjustment of the K-factor(s). The fluid plate
uses the K-factor(s) to calculate the volume dispensed.
If the set value is not correct, the system still delivers
repeatable flow rates; however, the reported value may
not be correct. See Verify Flow Meter Calibration,
page 38, for additional K-factor information.
Table 5: Flow Meter K-Factors
Part
Description
246652
High Resolution Helical
Gear Meter
246340
Heated Helical Gear
Meter
Set Flow Meter K-Factor
NOTE: In systems without a flow meter, the flow
meter settings will be grayed out.
1. With the system in setup mode, navigate to the Fluid
Plate set of screens.
2. Press
to scroll to the Flowmeter Set-
tings screen (screen 4).
3. Press
to access the fields to make changes.
F
. 25
IG
System Setup
K-Factor
7000
3500
31