Technical Data - Graco PCF Instructions And Parts

Precision dispense system
Table of Contents

Advertisement

Technical Data

Technical Data
*Minimum Flow Rates . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 cc/minute with high-resolution (ambient) helical flow
*Maximum Flow Rates . . . . . . . . . . . . . . . . . . . . . . . . . . . 7500 cc/minute with high-resolution (ambient) helical flow
Maximum Fluid Working Pressure
feed pressure to fluid plate (cartridge regulator) . . . .
feed pressure to fluid plate (mastic regulator) . . . . . .
at regulator outlet. . . . . . . . . . . . . . . . . . . . . . . . . . . .
at regulator outlet with electric heat components . . .
Minimum Fluid Working Pressure (at regulator outlet) . . . 100 psi (0.7 MPa, 7.0 bar)
Air Supply Pressure Range . . . . . . . . . . . . . . . . . . . . . . . 60-120 psi (0.4 - 0.8 MPa, 4.1- 8.3 bar) - 10 Micron filtra-
Fluid Filtration Required . . . . . . . . . . . . . . . . . . . . . . . . . . 30 mesh (500 micron) minimum
*Viscosity Range of Fluids . . . . . . . . . . . . . . . . . . . . . . . . 10000 to 1000000 cps with helical flow meter
*Minimum Dispensed Shot Size . . . . . . . . . . . . . . . . . . . . 3 cc with high-resolution (ambient) helical flow meter
Wetted Parts (meters and fluid plates) . . . . . . . . . . . . . . . 303, 304, 321, 17- 4 stainless steel; tungsten carbide,
Power Requirements
100-240 Vac. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
240 Vac . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Power Supply Voltage Range. . . . . . . . . . . . . . . . . . . . . . 100-240 Vac, 50-60 Hz, single phase
Operating Temperature Range
control center . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
heated fluid plate . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ambient fluid plate . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating Humidity Range. . . . . . . . . . . . . . . . . . . . . . . . 0 - 90% non-condensing
* Flow rates and viscosities are general estimates. Flow rates drop as viscosity increases. Fluids are expected to
shear under pressure. New applications or fluids should always be tested to determine proper line sizes and equip-
ment selections. See your Graco Authorized distributor for other capabilities.
106
meter
50 cc/minute with heated helical flow meter
meter
22,500 cc/minute with heated helical flow meter
37,500 cc/minute with separate flow meter
6000 psi (41.1 MPa, 414 bar)
5000 psi (34.5 MPa, 345 bar)
4500 psi (31.0 MPa, 310 bar)
3500 psi (24.1 MPa, 241 bar)
tion required
6 cc with heated helical flow meter
PTFE, steel, fluoroelastomer
full load 1.4A, fuse rating-2.5A
full load-4A, fuse rating-4A
40°F (4°C) - 120°F (49°C)
40°F (4°C) - 400°F (204°C)
40°F (4°C) - 120°F (49°C)
313377B

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents