Install Communications Gateway Module Interface

Module Description
The Communications Gateway Module (CGM) provides
a control link between the PCF system and a selected
fieldbus. This provides the means for remote monitoring
and control by external automation systems.
See System Setup, page 28, for details on controlling
the PCF system through the CGM.
Data Exchange
Data is available by block transfer, cyclic transfer,
change of state triggered, and explicit access to individ-
ual attributes as defined by the fieldbus specification.
NOTE: The following system network configuration
files are available at www.graco.com
EDS file: DeviceNet or EtherNet/IP fieldbus net-
works
GSD file: PROFIBUS fieldbus networks
SDML: PROFINET fieldbus networks
CGM Status LED Signals
Signal
Green on
System is powered up
Yellow
Internal communication in progress
Red
CGM hardware failure
Solid
*Red
Data map load failure
(7 flashes)
Incorrect data map for fieldbus type
No data map loaded
*The red LED (CF) will flash a code, pause, then repeat.
24
Description
Install Fieldbus Connections
Connect cables to fieldbus per fieldbus standards.
PROFINET
NS
F
. 16: PROFINET Fieldbus Connections
IG
The Ethernet interface operates at 100Mbit, full duplex,
as required by PROFINET. The Ethernet interface is
auto polarity sensing and auto-crossover capable.
Network Status (NS)
State
Description
Off
Offline
Green
On-line,
(RUN)
Flashing
On-line,
Green
(STOP)
MS
Link
TI11814A
Comments
No power
No connection with IO
Controller
Connection with IO Con-
troller established
IO Controller with RUN
state
Connection with IO Con-
troller established
IO Controller in STOP
state
313377B