12.0 ABSOLUTE MAXIMUM RATINGS
Supply Voltage, Vcc
Input Voltage
Current Any signal pin
Operating free air temperature range
Storage Temperature range
Latch up
Stresses beyond those listed under 'Absolute Maximum Ratings' may cause damage to the device.
These are stress ratings only and operation of the device at these or any other condition(s) beyond
those indicated in the 'Recommended Operating Conditions' section of this specification is not
implied. Exposure to absolute maximum rated conditions for extended periods may affect device
reliability.
13.0 RECOMMENDED OPERATING CONDITIONS
Symbol
Parameter
V
Supply Voltage
cc
V
High Level Input
ih
Voltage
V
Low Level Input
il
Voltage
V
High Level Input
ih
Voltage
V
Low Level Input
il
Voltage
I
Input Current High
ih
I
Input Current Low
il
I
Input Current Low
il
V
Output Voltage High
oh
V
Output Voltage Low
ol
DRAFT 11
Test Conditions
V
= min, V
= max
ih
il
All inputs except SDA & SCL
All inputs except SDA & SCL
SDA & SCL
SDA & SCL
Vcc = max
TEST1, TEST2 = 0V
TEST3, TEST4, TEST5 are
not connected
Vcc = max
Except Reset
TEST1, TEST2 = 0V
TEST3, TEST4, TEST5 are
not connected
Reset
Vcc = min
All standard outputs
I
60A
oh
600A
6mA
Vcc = min
All standard outputs
I
60A
ol
600A
Table 6: Recommended Operating Conditions
'EUROTEXT'
6.5V
Vcc + 0.5V
20mA
0ºC to 70ºC
-65ºC to 150ºC
250mA @ 25ºC
min
nom
4.75
5.00
0.7 Vcc
3.0
-1.5
Vcc - 100mV
Vcc - 200 mV
3.76
15-Feb-96
CF70200
max
unit
5.25
V
V
0.2
V
Vcc
V
1.5
V
A
1
A
-1
A
-7.0
V
-100
mV
500
mV
23
1Q96