Turning on/off the under 1 watt standby mode
The under 1W standby mode is always switched on at the factory.
(After the lights go off and with the garage door closed.)
Switch off under 1 watt standby:
1. Disconnect device from the mains.
2. Press the UP and DOWN buttons on the back on the adjusting
panel simultaneously and hold.
3. Connect the device again while the buttons are still pressed.
4. After about 5 seconds the opener's light flashes 10 times as
confirmation.
Note: Every time the opener is disconnected from the
mains, the opener's light flashes 10 times during reconnection to
indicate that the under 1 watt standby mode is off.
Switch on under 1 watt standby: See activation
P.
Cycle counter
This garage door opener features a cycle counter
(open/close = 1 cycle).
1. Pull plug.
2. Simultaneously press and hold round and sqare button on the
backside of the opener.
3. While holding the buttons insert plug.
4. After approx. 5 sec the LED indicates the number of cycles (for
every 1000 cycles the LED flashes once). Release buttons.
31

BPA500: Special Features

Timer to close
Description of the operation:
The garage door opener closes the garage door automatically from the
fully open position after a pre-programmed period of time.
For this, the photo cells must be connected to the garage door opener
according to EN60335-2-95.
Activating:
1.
Press the P button and the MINUS (-) button simultaneously for
about 3 seconds.
2.
When you release the buttons, the LED next to the S button turns
on and the operator lighting flashes twice as confirmation that the
garage door opener is in programming mode.
3.
Each time you press the PLUS (+) button the time period increases
by 10 seconds. Maximum 180 seconds are possible (= pressing 18
times).
4.
Each time you press the MINUS (-) button the time period reduces
again by 10 seconds (up to a minimum of 10 seconds).
5.
To save the desired time period, press the P button. To confirm the
programming, the operator lighting flashes once.
Disabling:
1.
Press the P button and the MINUS (-) button simultaneously for
about 3 seconds.
2.
The operator lighting will flash twice to confirm that the garage door
opener is in the disable mode.
3.
Press P button once.
4.
The operator lighting flashes once to confirm that the automatic
closing function has been disabled.
Information:
Automatic closing only works from the fully open position (garage
door must have reached the end position OPEN).
If the light barrier is interrupted during closing, the garage door
goes back to the fully open position and remains there until the
obstacle has been removed and after the programmed time period
has elapsed again.
Once the garage door opener is in programming mode, the next
button press must be carried out within 30 seconds, or else the
programming mode is cancelled. In this case, the operator lighting
flashes five times.
If the time period needs to be subsequently changed, for example,
from 60 to 80 seconds the PLUS (+) button must be pressed eight
times in the programming mode, as every new programming starts
at 0 seconds.
Troubleshooting:
The garage door opener does not operate without the light barrier.
No error! Connecting the light barrier once is absolutely necessary.
Cycle counter
The garage door opener can display the number of cycles (OPEN/
CLOSE = 1).
1.
Disconnect garage door opener from power supply
2.
Press and hold the P and S buttons
3.
Connect the garage door opener again while the buttons are still
pressed
4.
After all three LEDs have flashed once and the operator lighting is
switched on, the LED near the S button starts flashing after appro-
ximately 5 seconds (once every 1000 cycles). Release the buttons.
32

Operation of the door opener

Automatic opening / closing of the door:
The door opener can be operated using the following devices:
• Remote control: Press the button until the door starts to move.
• Wall switch (if this accessory is installed): Press the pushbutton until
the door starts to move.
Manual opening of the door (by hand):
If possible, the door must be closed completely. Weak or
defective springs can cause a rapid shutting down of the
open door, which can lead to property damage or serious
personal injury.
RELEASE: Briefly pull the red handle down. Then open the door by
hand. Open close door without pulling the cable!
RECONNECT: The lockout feature prevents the trolley from reconnec-
ting automatically. Push the green button on the trolley. With the next
door movement the system will reconnect.