Instructions for Auto-Close Feature
Description of feature: The photo cells must be installed
(required by EN60335-2-95).
Activate:
Push square and DOWN button simultaneously until th eoperator
light blinks. 1 push UP button = 10 seconds. up to 180 sec. possi-
ble (18x) During countdown the down button flashes. To complete
programming push square button.
Deactivate:
Push square and DOWN button simultaneously until th eoperator
light blinks. To complete programming push square button.
Notes:
- The auto-close timer resets if the IR sensors are interrupted.
- In the partial open position automatic close is not possible.
- The garage door operator must have reached the programmed
UP limit to activate the auto-close timer.
Troubleshooting:
Question: Operator will not work anymore without IR sensor.
Solution: Correct. IR sensors are mandatory once connected.
A full logic board reset is required.
E.
Change from fast speed to slow speed Description of feature:
The garage door opener chooses the necessary speed automati-
cally.
Change speed:
1. Move the door to the fully closed position.
2. Push UP and DOWN buttons simultaneously until operator light
blinks.
Attention: One piece doors, Canopy garage doors and any other
type of swing-out doors must be operated with slow speed. For
safety reasons, below 1.9m of travel length the speed is slow.
F.
OPEN, STOP or CLOSE programming of the remote control.
Description of feature:
Each remote control button can be programmed to either OPEN,
STOP or CLOSE the door.
OPEN:
Push yellow round button and UP button simultaneously until the
LED goes on. Now push a selcted button on the remote control for
OPEN only and wait for the operator light to flash.
STOP:
Push yellow round button and square button simultaneously until
the LED goes on. Now push another selcted button on the remote
control for STOP only and wait for the operator light to flash.
CLOSE:
Push yellow round button and DOWN button simultaneously until
the LED goes on. now push a third button on the remote control for
CLOSE only and wait for the operator light to flash.
G.
Holiday Mode (requires 78EV wall control):
Portable remote controls do not function if this feature is activated.
H.
Program remote control via wall control
(requires 78EV wall control).
I.
Operator light control (requires 78EV wall control):
The operator light can beswitched on and off at any time.Automatic
lighting (only with light barrier and wall bracket) When the light bar-
rier is interrupted, the lighting automatically switches on during the
opening of the door. Activation: Press and hold the "LIGHT" button
on the wall bracket for 10 seconds. Deactivation: see activation.
J.
Keyless entry (requires 747EV wireless keypad):
Enter a 4 digit code of your choice to operate the door.
K.
Temporary access (requires 747EV wireless keypad):
A temoprary code can be programmed to allow limited acces to the
garage (by time or number of openings).
L.
One button close feature (requires 747EV wireless keypad):
Without having the access code the door can be closed from any
position (not opened).
M.
MyQ (requires 828EV gateway):
Allows operating your garage door opener via internet or a
compatible mobile phone.
N.
Power supply for external devices (terminal 30V)
30VDC/max. 50mA
Note: For external (universal) receivers, the under 1 watt standby
mode must be turned off.