SCP-FLL814-012-04H
Alarms
HOURLY ES
DAILY ES
HOURLY SES
DAILY SES
86
Table 19. ISDN Alarm Thresholds
Value
1 to 255
ISDN hourly ES alarm is generated if the
accumulated hourly ES count at the COLU/RTLU
reaches or exceeds this threshold
1 to 4095
ISDN daily ES alarm is generated if the
accumulated daily ES count at the COLU/RTLU
reaches or exceeds this threshold
1 to 127
ISDN hourly SES alarm is generated if the
accumulated hourly SES count at the COLU/
RTLU reaches or exceeds this threshold
0 to 2047
ISDN daily SES alarm is generated if the
accumulated daily SES count at the COLU/RTLU
reaches or exceeds this threshold
Description
ADC Telecommunications, Inc.
April 22, 2003
Default
40
100
10
25