Table 22. Pots Options - ADC PG-FlexPlus FLL-814 Manual

24 channel integrated central office line unit
Table of Contents

Advertisement

April 22, 2003
Alarm
POTS Ringing Frequency
Local Loop Length
ADC Telecommunications, Inc.

Table 22. POTS Options

Value
20 HZ
Sets the ring generator frequency for all POTS circuits
served by the RTLU
25 HZ
30 HZ
SHORT
All POTS circuits support short subscriber drops and
results in slightly reduced power consumption from
the CO battery
LONG
All POTS circuits support standard length subscriber
drops. The power consumption from the CO battery
matches the published specifications
Description
SCP-FLL814-012-04H
Default
20 HZ
LONG
95