April 22, 2003
System Options
Subscriber Test Response
Mode
RT Auto Logout
PG-FlexPlus System ID
(24 chars max)
Allow System Provisioning
from RTLU
* RT Sealing Current
* RT SEALING CURRENT option is displayed only on a locally powered system.
ADC Telecommunications, Inc.
Table 12. System Options
Value
NONE
Disables the test and there will be no
response
TA-909
Performs the subscriber drop test at the
RTLU and presents the TA-909 resistive
signatures at the PMU
DISABLED
Auto logout feature is disabled
5
Screens session logs out after 5 minutes of
inactivity
30
Screens session logs out after 30 minutes
of inactivity
60
Screens session logs out after 60 minutes
of inactivity
24 Alphanumeric
Configurable identification string for the
Characters
system can be up to 24 characters. The
maximum
System ID is always visible at the bottom of
every screen. There are no special rules for
changing the System ID. Any printable
character, including space, is valid.
DISABLED
Disables configuration from the RTLU
ENABLED
Allows configuration from the RTLU
DISABLED
Single Span: Disables current flow between
the CO and RT
Doublers Used: Disables current flow
between the last doubler and RT
ENABLED
Sealing Current load is automatically
applied for a period of 15-20 seconds, once
every 24 hours at the system clock time of
00:05
SCP-FLL814-012-04H
Description
Default
TA-909
DISABLED
PG-FlexPlus
DISABLED
DISABLED
67
Need help?