LTPH-TP-1034-01, Issue 1
Table 5
below describes the Standard Config menu options and
menu options. Selections in bold type are the factory default settings.
Front-Panel
Standard Config
Display
Menu Options
Code
Loopback
LBTO
Timeout
Loop Attenuation
LATT
Threshold
Margin Threshold
MARG
DS1 Frame
FRMG
Formatting
DS1 Line Coding
DS1
H2TU-C
EQL
Equalization
See
"H2TU-C
Equalization
(EQL) Option." on
page
20.
H2TU-R Line
RLBO
Buildout
Alarm Pattern
ALMP
See
"Alarm
Pattern (ALMP)
Option." on
page
20.
H2TU-R TLOS
TLOS
Loopback
H2TU-C-231 List 4E
Table 5. H2TU-C-231 List 4E Standard Config Menu Options
Selection
Description
NONE
Disables automatic time-out cancellation of all loopbacks.
20
Sets automatic cancellation of all loopbacks to 20 minutes after initiation.
60
Sets automatic cancellation of all loopbacks to 60 minutes after initiation.
120
Sets automatic cancellation of all loopbacks to 120 minutes after initiation.
0 through
Determines the maximum loop attenuation before an alarm is declared. Zero
40 dB
disables the alarm. The loop attenuation threshold can only be set through the
maintenance screens.
32 dB
Default value.
0 to 15 dB
Determines the minimum allowable margin below which a system alarm can
occur. Zero disables the alarm. The Margin (Alarm) Threshold can only be set
through the maintenance screens.
5 dB
Default value.
AUTO
Configures the HiGain HDSL2 system to operate in an auto-framing (AUTO)
mode in which it continuously searches the input DS1 bit stream for a valid
SF or ESF frame pattern. Both line and path performance parameters are
maintained. Unframed payloads will cause the ES-P and SES-P counters to
increment.
UNFR
Configures the HiGain HDSL2 system to operate in an unframed mode. This
mode disables the auto framing process and forces the system to function as
a transparent bit pipe. Only line parameters are considered when monitoring
DS1 performance.
B8ZS
Places both the H2TU-C and H2TU-R into their B8ZS modes.
AMI
Places both the H2TU-C and H2TU-R into their AMI modes.
EXT
Disables the H2TU-C internal equalizer, allowing connection of external
equalizer hardware.
0
Sets the Equalizer to DSX-1 for 0 to 132 feet.
133
Sets the Equalizer to DSX-1 for 133 to 265 feet.
266
Sets the Equalizer to DSX-1 for 266 to 398 feet.
399
Sets the Equalizer to DSX-1 for 399 to 532 feet.
533
Sets the Equalizer to DSX-1 for 533 to 655 feet.
Sets the DS1 receive level output toward the Customer Interface (CI).
0 dB
Sets the DS1 RLBO level toward the CI to 0 dB.
-7.5 dB
Sets the DS1 RLBO level toward the CI to -7.5 dB.
-15.0 dB
Sets the DS1 RLBO level toward the CI to -15.0 dB.
AIS
Enables the HiGain HDSL2 system to output an AIS payload at its DS1 ports
for LOSW and LOS DS1. For priority resolution, see
LOS
Enables the HiGain HDSL2 system to output an LOS condition at its DS1 ports
for LOSW and LOS DS1.
ENA
Enables a logic loopback at the H2TU-R when an LOS occurs at its DS1 input,
if enabled at the H2TU-R. For priority resolution, see
DIS
Disables Transmit Loss of Signal (TLOS) logic loopback.
September 28, 2001
Table 6 on page 18
describes the ADC Config
Figure 26 on page
Provisioning
46.
Figure 26 on page
46.
Continued
17

Advertisement

Table of Contents
loading

Table of Contents