152-388-100-02, Issue 2
Table 5
describes the Standard Config screen options and lists their front-panel display codes.
describes the ADC Config screen options. Selections in bold typeface are the factory default settings.
Table 5. HiGain Line Unit List 1 Standard Config Screen Options
Screen
Standard Config
Display
Screen Options
Code
Loopback
LBTO
Timeout
Loop Attenuation
LATT
Threshold
Margin Threshold
MARG
DS1 Frame
FRMG
Formatting
DS1 Line Coding
DS1
(see
"DS1 Line
Coding (DS1)
Option" on
page
19)
H2TU-C
EQL
Equalization
See
"H2TU-C
Equalization
(EQL) Option." on
page
19.
H2TU-R Line
RLBO
Buildout
Alarm Pattern
ALMP
H2TU-C-388 List 1
Selection
Description
NONE
Disables automatic time-out cancellation of all loopbacks.
20
Sets automatic cancellation of all loopbacks to 20 minutes after initiation.
60
Sets automatic cancellation of all loopbacks to 60 minutes after initiation.
120
Sets automatic cancellation of all loopbacks to 120 minutes after initiation.
0 through 40 dB Determines the maximum loop attenuation before an alarm is declared. The
loop attenuation threshold can only be set through the HiGain HDSL2
maintenance screens.
35 dB
Default value. Zero disables the alarm.
0 to 15 dB
Determines the minimum allowable margin below which a system alarm can
occur. Zero disables the alarm.The Margin Alarm Threshold can only be set
through the HiGain HDSL2 maintenance screens.
4dB
Default value.
AUTO
Configures the HiGain system to operate in an auto-framing (AUTO) mode. It
detects and locks to both SF or ESF DS1 frame patterns. Line and path
performance parameters are maintained and displayed. Unframed payloads
will cause the ES-P and SES-P counters to increment.
SF
Configures the HiGain system to search for the SF framing pattern at its DS1
input.
ESF
Configures the HiGain system to search for the ESF framing pattern at its DS1
input.
UNFR
Configures the same as AUTO except unframed payloads do not cause the
ES-P and SES-P counters to increment.
AUTO
The H2TU-C-388 and H2TU-R monitor the incoming DS1 bit streams for the
B8ZS code. If the H2TU-R detects this code, the H2TU-C enters B8ZS output
mode. The H2TU-C reverts back to AMI output mode if no B8ZS codes are
received at the H2TU-R input for 5 seconds. Similarly, when the H2TU-C
detects the B8ZS code, the H2TU-R enters B8ZS mode and returns to AMI
mode if no B8ZS code is received at the H2TU-C input for 5 seconds.
B8ZS
Places both the H2TU-C-388 and H2TU-R into B8ZS mode.
AMI
Places both the H2TU-C-388 and H2TU-R into AMI mode.
0
Sets the Equalizer to DSX-1 for 0 to 132 feet.
133
Sets the Equalizer to DSX-1 for 133 to 265 feet.
266
Sets the Equalizer to DSX-1 for 266 to 398 feet.
399
Sets the Equalizer to DSX-1 for 399 to 532 feet.
533
Sets the Equalizer to DSX-1 for 533 to 655 feet.
0 dB
Sets the DS1 receive level output toward the Customer Interface (CI). Can only
be set through the HiGain HDSL2 maintenance screens.
-7.5 dB
Sets the DS1 RLBO level toward the CI to -7.5 dB.
-15 dB
Sets the DS1 RLBO level toward the CI to -15.0 dB.
AIS
Enables the HiGain system to output an AIS payload at its DS1 ports for LOSW
and DS1 LOS. See
LOS
Enables the HiGain system to output an LOS condition at its DS1 ports for
LOSW and DS1 LOS.
June 6, 2000
Figure 25 on page 38
for LOS/AIS response priorities.
Provisioning
Table 6 on page 18
Continued
17