Summary of Contents for ADC HiGain H2TU-C-231 List 3F
Page 1
ANUAL HiGain H2TU-C-231 List 3F Line Unit Product Catalog: H2TU-C-231-L3F CLEI: VACJ4T3E...
Page 2
Contents herein are current as of the date of publication. ADC reserves the right to change the contents without prior notice. In no event shall ADC be liable for any damages resulting from loss of data, loss of use, or loss of profits, and ADC further disclaims any and all liability for indirect, incidental, special, consequential or other similar damages.
Page 3
Unpack each container and inspect the contents for signs of damage. If the equipment has been damaged in transit, immediately report the extent of damage to the transportation company and to ADC DSL Systems, Inc. Order replacement equipment, if necessary.
Page 4
Inspecting Shipment LTPH-UM-1149-01 June 12, 2002 H2TU-C-231 List 3F...
LTPH-UM-1149-01 Table of Contents ABLE OF ONTENTS Overview ____________________________________________________________________________ 1 Features ..............................1 Applications ............................2 Front Panel __________________________________________________________________________ 3 Installation___________________________________________________________________________ 7 Verification ............................8 Verification without an H2TU-R Remote Unit ..............8 Verification with an H2TU-R Remote Unit ................8 Provisioning__________________________________________________________________________ 9 Displaying System Parameter Settings ....................9 Accessing the Provisioning Screens ....................9 Connecting to a Maintenance Terminal................9 Logon Screen ........................10...
Page 6
Table of Contents LTPH-UM-1149-01 Testing _____________________________________________________________________________ 48 System Alarms..........................48 Alarm Option for the Digital Loop Carrier Feed .............. 49 Retiring System Alarms ....................49 Remote LOS and AIS Response ..................50 OCT55 Test Pattern with AMI Line Code ..................50 Loopback Operation ........................
Page 7
5. Inventory Screen............................13 6. Config Menu..............................14 7. Config Menu - Standard Options (defaults shown)..................15 8. Config Menu - ADC Options (defaults shown) ...................15 9. Config Menu - Set to Factory Defaults ......................24 10. Config Menu - Master Clear ........................25 11. Sectionalized Analysis of the DS1 Interface....................26 12.
Page 8
4. Logon Screen Menus ..........................11 5. H2TU-C-231 List 3F Standard Config Menu Options ................16 6. H2TU-C-231 List 3F ADC Config Menu Options..................17 7. DS1/DSX-1 24-Hour PM Threshold ......................20 8. Response to H2TU-R DS1 Frame Conversion Options ................21 9.
LTPH-UM-1149-01 Overview VERVIEW The H2TU-C-231 List 3F (H2TU-C) line unit is the Central Office (CO) side of a T1 transmission system. The HiGain HDSL2 product family is fully compliant with the HDSL2 standard ANSI T1.418. The H2TU-C, when used with an H2TU-R remote unit, transmits a 1.544 Mbps payload on one unconditioned copper pair over the full Carrier Service Area (CSA) range.
Overview LTPH-UM-1149-01 – Bipolar Violation Transparency (BPVT) options – Bit Error Rate (BER) alarm – Power Back Off - Customer (PBOC) and Power Back Off - Network (PBON) options for configuring power output levels – Loss of Signal/Alarm Indication Signal (LOS/AIS) payload alarm option –...
LTPH-UM-1149-01 Front Panel RONT ANEL Figure 1 shows the H2TU-C-231 List 3F front panel. Table 2 on page 5 describes the front-panel components. For pinout diagrams of the H2TU-C-231 List 3F card-edge connector and craft port, refer to “Appendix A - Specifications”...
Page 12
Front Panel LTPH-UM-1149-01 Table 1. Front-Panel Description Front-Panel Feature Function Front-panel display Displays four-character status, provisioning, and alarm system messages. The front-panel display illuminates when power is initially applied. To conserve power the display only remains on for 5 minutes. Using the MODE or LBK pushbuttons reactivates the display and restarts the 5-minute timer.
LTPH-UM-1149-01 Front Panel Table 2 lists the front-panel display messages. The four-character display reports the code of an alarm, loopback, or diagnostic message and, in some cases, is followed by a second four-character message that modifies the first message with a value or current configuration setting. Table 2.
Page 14
Front Panel LTPH-UM-1149-01 Table 2. Front-Panel Display Messages (Continued) Message Full Name Description LOOPBACK MESSAGES CLOC Customer Local Loopback Signal from customer is looped back to the customer at the H2TU-R. COLB Central Office Loopback Dual loopback at the H2TU-C. CREM Customer Remote Loopback Signal from customer is looped back to the customer at H2TU-C.
Upon receipt of the equipment, inspect the contents for signs of damage. If the equipment has been damaged in transit, immediately report the extent of damage to the transportation company and to ADC. When installing an H2TU-C in a chassis, be sure to wear an antistatic wrist strap. Avoid touching components on the circuit board.
Installation LTPH-UM-1149-01 ERIFICATION Once the H2TU-C is installed, verify that it is operating properly. To do this, monitor the following: • Status LED • Status messages reported by the front-panel display (Table 2 on page 5 lists the status messages). For information regarding turn-up instructions, see the Help menu and select Turn-up Aid.
LTPH-UM-1149-01 Provisioning ROVISIONING ISPLAYING YSTEM ARAMETER ETTINGS To scroll through the current settings of all system parameters, press the MODE pushbutton for 3 or more seconds. The H2TU-C displays the following parameters: • Software version number • List number • Type of frame pattern received from the DSX-1 •...
(a) Legacy management units require use of control keys instead of arrow keys. Menu bar Monitor Performance Event Log Config Inventory Report Rlogon Help +------------------------------------------+ ADC DSL Systems, Inc. HiGain HDSL2 Voice: 800.638.0031 714.730.2400 +------------------------------------------+ .ID: xxxx--xxxx--xxxx—-xxxx 04/10/2002 22:46:19 H2TU-C System: OKarm...
Page 19
Figure 23 on page Config Provides standard configuration options, ADC options, date and time setting, and a reset option (factory settings). Also provides a master clear option that clears all performance, alarm, and event log entries. Selecting the Config menu after a remote...
Standard and ADC configuration options. Standard options are those supported by HiGain HDSL2 units when connected to units from other vendors. ADC options are an extended set of options that are only available when using HiGain units exclusively. For a description of each...
Page 23
| H2TU-R DS1 Frame Conversion (CONV) : ACON +-------------------------------------------------+ Use <Spacebar> to cycle through option settings and <Enter> to activate .ID: xxxx--xxxx--xxxx—-xxxx 04/10/2002 23:49:36 H2TU-C System: OKarm Figure 8. Config Menu - ADC Options (defaults shown) H2TU-C-231 List 3F June 12, 2002...
Provisioning LTPH-UM-1149-01 Table 5. H2TU-C-231 List 3F Standard Config Menu Options Front-Panel Standard Config Display Selection Description Menu Options Code Loopback Timeout LBTO NONE Disables automatic time-out cancellation of all loopbacks. 20 min Sets automatic cancellation of all loopbacks to 20 minutes after initiation. 60 min Sets automatic cancellation of all loopbacks to 60 minutes after initiation.
Configures the power output levels of the H2TU-R customer unit toward the Options” on page network to comply with the Enhanced template as defined in Section 6.1.4.2 of ANSI T1/E1.4. Table 6. H2TU-C-231 List 3F ADC Config Menu Options Front-Panel ADC Config Display...
Page 26
Provisioning LTPH-UM-1149-01 Table 6. H2TU-C-231 List 3F ADC Config Menu Options (Continued) Front-Panel ADC Config Display Selection Description Menu Options Code Special Loopback SPLB GNLB Configures the HDSL2 system to respond to the generic inband loopback codes. Mode A1LB and...
Page 27
LTPH-UM-1149-01 Provisioning Table 6. H2TU-C-231 List 3F ADC Config Menu Options (Continued) Front-Panel ADC Config Display Selection Description Menu Options Code H2TU-R DS1 Frame CONV Framing functionally determined by the framing option. Frame format Conversion conversion is inhibited at the H2TU-R.
Page 28
Provisioning LTPH-UM-1149-01 The BPV count is converted into BPVs at the distant end during the following second at a rate of 1 BPV every 128 DS1 bits up to a maximum of 12000 (BER = 7.7 x 10 ). This maximum rate is more than adequate since it exceeds the maximum 10 BER required by most DLC systems.
LTPH-UM-1149-01 Provisioning Table 8. Response to H2TU-R DS1 Frame Conversion Options ACON Option FCON Option Case Number NET Transmit CPE Transmit NET > CPE NET > CPE NET < CPE NET < CPE → → ESF ← SF ESF ← SF →...
Page 30
Provisioning LTPH-UM-1149-01 Table 10. SuperFrame Format Frame Bits SF Number Terminal Framing Bit SuperFrame Signaling Bit ESF-RAI to SF-RAI Overwrite (ROVR) Option. If the ESF-RAI to SF-RAI Overwrite (ROVR) option is enabled, it allows a network ESF-RAI or ESF-RAI-CI pattern to be converted into a CPE SF-RAI or SF-RAI-CI pattern, and overwrites bit 2 of every DS0 channel with a zero.
Page 31
LTPH-UM-1149-01 Provisioning in the DS1 signal and is 01111100 11111111 (right to left). This results in a repetitive pattern of 6176 bits. If the first bit is numbered bit 0, bits 3088, 3474, and 5790 are logical zeroes and all other bits in the pattern are logical ones.
Event Log Config Inventory Report Rlogon Help +-----------------------+ | Standard Options -> | | ADC Options -> | | Date and Time -> | | Master Clear Set Factory Defaults..| +-----------------------+ SETTING FACTORY DEFAULTS...SERVICE MAY BE INTERRUPTED! ARE YOU SURE (Y/N)? .ID:...
Event Log Config Inventory Report Rlogon Help +-----------------------+ | Standard Options -> | | ADC Options -> | | Date and Time -> | Master Clear..….…..…….| | Set Factory Defaults +-----------------------+ Clear ALL performance, alarm and event log entries. Are you sure (Y/N)? .ID:...
Provisioning LTPH-UM-1149-01 ONITORING YSTEM CTIVITY AND ERFORMANCE The HDSL2 system provides the following maintenance screens for monitoring system activity and assessing performance. • The Monitor screen provides a graphical representation of circuit activity and allow initiation of loopbacks. • The Performance screens provide current, 25-hour, 48-hour, and 31-day performance histories and a continuous alarm history.
LTPH-UM-1149-01 Provisioning • RAI-CI insertion toward the network upon receiving RAI from the CPE, if the signal from the network is not impaired • Loopback toward the network with AIS insertion to the CPE equipment • Adaptive frame format conversion if enabled in: –...
Provisioning LTPH-UM-1149-01 Table 11. Bit Error Indication of Margin and Pulse Attenuation Parameters Margin (dB) Pulse Attenuation (dB) Bit Errors Sent 5 or less 31 or higher 5 or less 26 - 30 5 or less 0 - 25 6 - 10 31 or higher 6 - 10 26 - 30...
Page 37
LTPH-UM-1149-01 Provisioning When prompted with the message: Are you sure (Y/N)?, press to initiate the loopback or cancel. For more information about loopbacks, see “Testing” beginning on page SPACEBAR ENTER To initiate a loopdown of all active loopbacks, press the to select LPDN, then press When prompted with the message: Are you sure (Y/N)?, press to initiate the loopdown or...
Provisioning LTPH-UM-1149-01 SING THE ERFORMANCE CREENS TO ERFORMANCE The Performance screens display: • CRC statistics for the HDSL2 or DS1 interface in 31-day, 48-hour, 25-hour, and current history reports. • Alarm statistics for the DS1 interfaces (Figure 23 on page 38 Figure 24 on page 38) or HDSL2 interfaces (Figure 25 on page...
Page 39
LTPH-UM-1149-01 Provisioning Monitor Performance Event Log Config Inventory Report Rlogon Help H2TU-R DS1 31 Day History (Page 1 of 3) ----------------------------------------------------------------------------- Date CV-L ES-L SES-L UAS-L CV-P ES-P SES-P UAS-P PRM-NE PRM-FE 03/11 03/12 03/13 03/14 03/15 03/16 03/17 03/18 03/19 03/20 03/21...
Provisioning LTPH-UM-1149-01 Blockage Indicator Statistics at the H2TU-R DS1 Interface Figure 18 is an example of an H2TU-R Blockage Indicator (BI) History screen as viewed from the H2TU-R following a remote logon. This screen can also be viewed when logged on locally at the remote unit. The BI statistics can also be retrieved using inband or Facility Data Link (FDL) access.
LTPH-UM-1149-01 Provisioning Performance History at the HDSL2 Interface The HDSL2 interface has 31-day, 48-hour, 25-hour, and current statistic screens for the H2TU-C. Figure 19 Figure 20 are examples of 31-day and 48-hour performance history screens. Figure 21 Figure 22 on page 36 are examples of 25-hour and current statistics performance history screens.
LTPH-UM-1149-01 Provisioning Table 14. Error Acronyms Used on the HDSL2 Performance History Screens Error Acronym Description Code Violation Total count of HDSL2 CRC errors. Errored Seconds Seconds with HDSL2 CRC ≥ 1 or LOSW ≥ 1 Severely Errored Seconds Seconds with HDSL2 CRC ≥ 50 or LOSW ≥ 1 Unavailable Seconds Based on 10 contiguous SES occurrences LOSWS...
Provisioning LTPH-UM-1149-01 Monitor Performance Event Log Config Inventory Report Rlogon Help H2TU-C DS1 Alarm History ----------------------------------------------------------------------------- Alarm First Last Status Count LLOS 04/10/02 00:00 04/10/02 02:05 ALARM LAIS 04/08/02 00:00 04/08/02 09:34 DBER DISABLED Press: C(l)ear Alarm History ----------------------------------------------------------------------------- Use <Space> to cycle through.. Interface H2TU-C DS1 choices and <Enter>...
Page 47
LTPH-UM-1149-01 Provisioning Table 15. DS1 Alarm Descriptions Screen Alarm Front-Panel Alarm Description H2TU-C DS1 ALARMS (see Figure 23 on page LLOS LLOS Line (Unit) Loss of Signal—Loss of the H2TU-C DSX-1 input signal. LAIS LAIS Line Alarm Indication Signal—Indicates an AIS (all ones) pattern is being transmitted from the local DS1 output port.
Provisioning LTPH-UM-1149-01 Alarm History at the HDSL2 Interface The HDSL2 Alarm History screens report alarms at the H2TU-C and the H2TU-R. Figure 25 shows the H2TU-C HDSL2 alarm history. Table 16 describes the alarms that are reported at the H2TU-C or H2TU-R. Monitor Performance Event Log...
LTPH-UM-1149-01 Provisioning SING THE YSTEM VENT OG TO RACK VENTS The System Event Log screen (Figure 26) displays 100 of the most recent events (most recent event displayed first) and provides the following information: • Origin tags to identify the source of a Write entry (see “Origin Tags”...
Provisioning LTPH-UM-1149-01 Event Log Messages Table 17 lists all the possible messages that can be displayed by the System Event Log screen. Table 17. Event Log Entry Messages Any DS1 Alarm History reset Any DS1 PM register reset Any HDSL2 Alarm History reset Any HDSL2 PM register reset Any Loop Down (any segment) Any Loop Up (any segment)
LTPH-UM-1149-01 Provisioning Origin Tags The origin tags identify the source of all Write entries and how an event occurred. The exact meaning is dependent on the type of event and the unit reporting the event. A Write entry changes a system parameter or an option setting, but it does not affect circuit status changes, such as alarms.
Provisioning LTPH-UM-1149-01 SING THE ECTIONALIZED VENT OG TO SOLATE ROUBLE The Sectionalized Event Log screen, shown in Figure 27, displays the date and time of the 100 most recent sectionalized events (most recent event displayed first) for all four legs of the H2TU-R DS1 interface. The screen provides a description of each event with the most recent event displayed first.
LTPH-UM-1149-01 Provisioning Sectionalized events isolate trouble to a particular circuit leg. For example, an ES listed under the NET-TX column indicates that an errored second condition exists on the NET-TX circuit leg beginning with the time stamp and continuing until an OK or other new event is recorded. Sectionalized events use the status definitions described in Figure 27 on page 44 and in...
Provisioning LTPH-UM-1149-01 SING THE EPORT The Report menu (Figure 29) provides screens containing status and performance monitoring data for line and remote units which can be downloaded to a file for analysis or future reference. Table 20 on page 47 describes the report types provided by the Report menu.
LTPH-UM-1149-01 Provisioning Table 20. Report Types Type Contains the following information: Full Report • Circuit and unit identifications • Product information • System configuration • Current performance statistics • Alarm history • Performance history • System event log Short Report •...
Testing LTPH-UM-1149-01 ESTING This section provides information about front-panel system alarms, LOS and AIS response, OCT55 test procedure, and loopback testing. YSTEM LARMS Table 21 summarizes all possible system alarms in order of priority as they appear on the line unit front panel. When multiple alarms occur, the front-panel display only reports the highest priority alarm.
LTPH-UM-1149-01 Testing Table 21. Front-Panel System Alarms Summary (Continued) Front-Panel Alarm Description To Inhibit Message xxx-MAL Margin Alarm The margin on the HDSL2 loop has dropped Set the Margin Alarm below the minimum threshold value set for the Threshold option to 0 system.
[DIS] pattern [AIS] AIS to CPE [ENA] [LOS] ALMP Pass on LOS to NET [AIS] ADC Option [AIS] Standard Option NAIS Send AIS to NET Default configurations [CI] are in bold. Send AIS-CI to NET Figure 30. H2TU-R LOS and AIS Response Priorities...
LTPH-UM-1149-01 Testing OOPBACK PERATION HiGain HDSL2 has a family of loopback options for analyzing circuit functionality. The loopback signal is transmitted and returned to the sending device for comparison. This allows you to verify the integrity of the HDSL2 channels to the H2TU-C, the H2TU-C DSX-1 interface and the DS1 channels to the customer. Loopback options include: •...
Testing LTPH-UM-1149-01 ENERIC OOPBACK OMMANDS The HDSL2 Generic Loopback (GNLB) commands allows the use of inband codes to loop up either NLOC (4-in-7) or NREM (3-in-7) towards the network. Additionally, these inband codes loop up CREM (6-in-7) or CLOC (5-in-7) towards the customer. Either loopup condition can be terminated (looped down) with the 3-in-5, SMJK loopdown code.
LTPH-UM-1149-01 Testing PECIAL OOPBACK OMMANDS In addition to the GNLB loopback command mode, an HDSL2 system can be configured for special loopback command modes. The H2TU-C can be configured from the maintenance terminal Monitor screen using the Config menu and Special Loopback Mode option. Once a loopback mode is activated, other loopback commands can be sent by a test set connected to the craft port of the H2TU-C or H2TU-R.
Testing LTPH-UM-1149-01 ANUAL OOPBACK ESSION A manual loopback session allows for any HDSL2 loopback selection as listed in Table 22 on page 52 with the exception of SmartJack loopbacks, which can only be issued by inband commands. Setting the Loopback Time-Out Option Before initiating a loopback session, verify that the Loopback Time-Out parameter is set to the desired setting.
LTPH-UM-1149-01 Testing Loopbacks can be terminated manually and exited from the MAN LPBK mode by simultaneously pressing the MODE and LBK pushbuttons for 3 or more seconds. If no loopback is active, the MAN LPBK mode automatically terminates after 30 seconds. All loopbacks, except dual loopbacks, can be initiated by inband commands in the DS1 payload.
Page 65
LTPH-UM-1149-01 Testing To perform the A2LB loopback test procedures: Send the inband Arming and NI LPBK code 11000 to the H2TU-C for at least 5 seconds. Monitor the output of the H2TU-C for the return of the pattern. Return of the pattern indicates one of the following: •...
Page 66
Testing LTPH-UM-1149-01 The Armed mode has an automatic time-out of 120 minutes, but this timer is reset to 120 for any of the following events: • Loopback terminates (manually or time-out) • Query • Alternate query • Far-End activate • Another ARM command This timer is inhibited while any of the valid command codes are being sent.
LTPH-UM-1149-01 Testing A3LB and A4LB Test Procedures The H2TU-C-231 List 3F can be looped back by sending the Addressable Office Repeater (AOR) LPBK activation code 1111-1111-0001-1110 (FF1E) for at least 5 seconds. This causes the H2TU-C to enter the NLOC state.
Performance Event Log Config Inventory Report Rlogon Help +-----------------------+ | Standard Options -> | | ADC Options -> | Signal Generator -> +--------------------------------------+ | Test Signal Generator | Test Signal Pattern : ALL 1 | Test Signal Linecode : AMI...
LTPH-UM-1149-01 Appendix A - Specifications A - S PPENDIX PECIFICATIONS Power HDSL2 Span Voltage 0 or -180 ±5 Vdc CO Supply -48 Vdc nominal (-42.5 Vdc to -56.5 Vdc) “Power Consumption” “Maximum Power Dissipation” “Maximum Current Drain” on page Electrical Protection Secondary surge and power cross protection on HDSL2 ports.
Appendix A - Specifications LTPH-UM-1149-01 OWER ONSUMPTION The three most important power parameters of an H2TU-C are its maximum power consumption, maximum power dissipation, and maximum current drain. Table 26 describes line-powered circuits on 9 kft, 26 AWG loops without a regenerator. Table 26.
LTPH-UM-1149-01 Appendix A - Specifications TTENUATION Each loop has no more than 35 dB of insertion loss at 196 kHz, with driving and terminating impedances of 135 Ω , as shown in Table 27 below. This is equivalent to no more than 28 dB loop attenuation. Table 27.
The H2TU-C provides a Network Management Control Bus on pin46 of the card-edge connector. This allows the various ADC Management System protocols to manage the H2TU-C through the HMU-319 HiGain Management Unit. Whenever the H2TU-C is under management, the MNGD message displays periodically on the front-panel display.
LTPH-UM-1149-01 Appendix A - Specifications RAFT Figure 34 shows the pinout for the craft port connector and its connection to a DB-9 or DB-25 connector on a maintenance terminal. Terminal DB-9 Connector (DTE) H2TU-C DB-9 Connector (DCE) TD (Transmit Data) RD (Receive Data) Terminal DB-25 Connector...
UNCTIONAL PERATION ADC HDSL2 technology provides full-duplex services at standard DS1 rates over copper wires between an H2TU-C and an H2TU-R, which comprise one HDSL2 system. ADC systems use ADC Overlapped Pulse Amplitude Modulation (OPAM) transceiver systems to establish a full-duplex, 1.552 kbps data channel between an H2TU-C and a remotely located H2TU-R.
ANSI T1.418-2000 HDSL2 standards. HiGain HDSL2 complies with GR-63-CORE, TR-TSY-000499, and GR-1089-CORE. The H2TU-C-231 List 3F is compatible with the following DS1 repeater shelves and associated equipment: • ADC HiGain HCS-417 (23-inch shelf) • ADC HiGain HCS-418 (19-inch shelf) •...
UPPORT ADC Customer Service Group provides expert pre-sales and post-sales support and training for all its products. Technical support is available 24 hours a day, 7 days a week by contacting the ADC Technical Assistance Center. • Quotation Proposals Sales Assistance •...
LTPH-UM-1149-01 Appendix E - Abbreviations E - A PPENDIX BBREVIATIONS ACO: Alarm Cutoff GFD: Ground Fault Detect ACQ: Acquisition GNLB: Generic Loopback AIS: Alarm Indication Signal ALM: Alarm ALRM: Alarm Condition H2TU-R: HiGain HDSL2 Remote Unit AMI: Alternate Mark Inversion HBER: HDSL2 Block Error Rate AOR: Addressable Office Repeater...
Page 78
Appendix E - Abbreviations LTPH-UM-1149-01 PRM-FE: Performance Report Messaging - Far End PRMN: Performance Report Messaging - Near End PRM-NE: Performance Report Messaging - Near End QoS: Quality of Service RAI-CI: Remote Alarm Indication-Customer Installation RAIS: Remote Alarm Indication Signal RDA: Remote Disconnect Alarm RLOS: Remote Loss of Signal...
ADC during the 90-day warranty period is, at ADC’s option, either (a) return of the price paid or (b) repair or replace of the software. ADC also warrants that, for a period of thirty (30) days from the date of purchase, the media on which software is stored will be free from material defects under normal use.
Page 80
ADC DSL Systems, Inc. 14402 Franklin Avenue Tustin, CA 92780-7013 Tel: 714.832.9922 Fax: 714.832.9924 Technical Assistance Tel: 800.638.0031 Tel: 714.730.3222 Fax: 714.730.2400 : LTPH-UM-1149-01 OCUMENT ISO 9001/TL 9000 ´,Bw¶2)¨ DNV Certification, Inc. REGISTERED FIRM 1234872...
Need help?
Do you have a question about the HiGain H2TU-C-231 List 3F and is the answer not in the manual?
Questions and answers