Configuration Submenu
Options
POTS Ringing Frequency
Subscriber Drop Test
Compatibility
HDSL Power Up
HDSL Fallback to Metallic Enabled
PG-Plus System (24 chars
max)
36
Table 8.
System Options Configuration Fields
Description
Default
20 Hz
The ringing frequency sent from the RT to the subscriber.
25 Hz
30 Hz
50 Hz.
OFF
System will not initiate nor operate with MLT loop test systems.
MLT
The system will initiate and operate with MLT loop test systems.
Enabled
In Metallic Fallback the system attempts to power up the HDSL line
every five minutes or anytime the HDSL pair is shorted for two seconds
and then opened. .
Disabled
inhibits the power-up sequence under any circumstances and the system
remains in Metallic Fallback
The system provides fallback to metallic operation on POTS channel 1
during system failures.
Disabled
The system provides no metallic connection during system failures.
This string can be up to
Configurable identification string for system. There are no special rules
24 characters, can be any
for changing the System ID.
printable character,
including space.
January 6, 2003
SCP-PLL720-020-03H